Multi-frequency averaged model and harmonic endogeny mechanism of single-inductor dual-output convertersOA
With the ever-increasing demand of the renewable energy generation technology,multiple-port power electronic equipment has brought more severe harmonic problem in power systems.Suppressing harmonics’priority is to deeply identify harmonic origins.This paper deals with harmonic endogeny mechanisms of single-inductor dual-output(SIDO)buck-boost converters theoretically and experimentally.First of all,multi-frequency averaged(MFA)model is proposed to describe nonlinear dynamical characteristics of the SIDO converter in both low-and high-frequency domain.Based on the MFA model,the nonlinear modal series representation is derived to obtain a closed-form approximate solution.It is found that as the proportional coefficient kpc increases,oscillation behaviors occur with four new harmonic components in the frequency domain,i.e.,fo1,fo2,fo3 and fo4.Bifurcation-induced harmonic analysis is performed to identify the dominant-oscillatory modals of the SIDO converter.It is shown that Hopf bifurcation takes responsibility for the occurrence of the harmonic frequency fo1.Unlike fo1,harmonic frequencies fo2,fo3,fo4 and many other beat frequencies are induced by interaction among dominant-oscillatory modals and fundamental frequency in terms of interaction-induced harmonic analysis method.Besides,second-order harmonic indices are used to evaluate the interaction effect of dominant-oscillatory modals on system with variation of key circuit parameters.Moreover,the harmonic stability boundaries are gained to guide design-oriented harmonic suppression.Finally,these experimental results are performed to verify those numerical and theoretical results.
Sun Yixin;Li Xiang;Lan Yi;Chen Sichao;Zhang Hao;Cui Donggang
State Key Laboratory of Electrical Insulation and Power Equipment,Xi''an Jiaotong University,Xi''an 710049,ChinaState Key Laboratory of Electrical Insulation and Power Equipment,Xi''an Jiaotong University,Xi''an 710049,China Qijiang Power Supply Company,State Grid Corporation of China,Qijiang 401420,ChinaState Key Laboratory of Electrical Insulation and Power Equipment,Xi''an Jiaotong University,Xi''an 710049,ChinaState Key Laboratory of Electrical Insulation and Power Equipment,Xi''an Jiaotong University,Xi''an 710049,ChinaState Key Laboratory of Electrical Insulation and Power Equipment,Xi''an Jiaotong University,Xi''an 710049,ChinaState Key Laboratory of Electrical Insulation and Power Equipment,Xi''an Jiaotong University,Xi''an 710049,China
信息技术与安全科学
Harmonic endogeny mechanismMulti-frequency averaged modelSingle-inductor dual-output convertersStability boudary
《Renewable Energy System and Equipment》 2026 (1)
P.22-32,11
supported by National Natural Science Foundation of China(Grant no.52277017).
评论