首页|期刊导航|Smart Power & Energy Security|Manifold property of GFL converter:Impact of modelling and operating condition

Manifold property of GFL converter:Impact of modelling and operating conditionOA

中文摘要

Grid-following(GFL)converters are essential components in integrating renewable energy sources,microgrids,HVDC circuits,and loads into modern power grids.The transient stability analysis of GFL converters has attracted significant research attention,with manifold-based methods emerging as a prominent analytical tool.While most studies have focused on the inverter mode,the transient stability characteristics and bifurcation phenomena in rectifier mode remain relatively unexplored.This paper investigates and summarizes the manifold characteristics and bifurcation behaviors of GFL converters,highlighting key distinctions between inverter and rectifier modes.It demonstrates that commonly used phasor models neglecting inductive line dynamics lead to inaccuracies,specifically causing an overestimation of the region of attraction(ROA)in inverter mode and an underestimation in rectifier mode.This discrepancy arises from differences in modeling,where inductive line dynamics introduce additional positive damping effects in the rectifier mode in modeling.Furthermore,rigorous proof is provided that limit cycles cannot exist in GFL rectifier mode,which is different from the inverter mode scenario.This paper compares various modeling approaches,including phasor models,electromagnetic transient(EMT)averaging models,and experimental validations.Additionally,hardware-in-the-loop(HIL)experiments are performed to confirm model validity.

Yifan Zhang;Yitong Li;Yunjie Gu;Cheng Ai;Timothy C.Green

Department of Electrical and Electronic Engineering,Imperial College,SW72AZ,London,UKState Key Laboratory of Electrical Insulation and Power Equipment,School of Electrical Engineering,Xi''an Jiaoting University,Xi''an,710049,ChinaDepartment of Electrical and Electronic Engineering,Imperial College,SW72AZ,London,UKState Key Laboratory of Electrical Insulation and Power Equipment,School of Electrical Engineering,Xi''an Jiaoting University,Xi''an,710049,ChinaDepartment of Electrical and Electronic Engineering,Imperial College,SW72AZ,London,UK

信息技术与安全科学

Grid-followingTransient stabilityManifoldLimit cycleRectifier modeHardware-in-loop

《Smart Power & Energy Security》 2026 (1)

P.1-10,10

supported partially by the National Natural Science Foundation of China under Grant 52307222partially by the Department of Electrical and Electronic Engineering,Imperial College Londonpartially by the School of Electrical Engineering,Xi''an Jiaotong University.

10.1016/j.spes.2026.04.001

评论