n型TOPCon光伏组件的弱光性能及其对系统PR的影响研究OA
RESEARCH ON LOW-IRRADIANCE PERFORMANCE OF n-TOPCon PV MODULES AND ITS IMPACT ON SYSTEM PR
随着n型TOPCon光伏组件的全球规模化应用,其弱光性能已成为影响系统能效比(PR)的关键因素之一,会显著影响光伏发电系统在实际工况下的能量产出.首先对光伏组件弱光性能的评价指标与关键影响因素进行了分析;然后通过开展多源实测数据对比,从主流光伏组件制造商的公开文档数据、第三方检测机构的实测数据、光伏组件制造商的出厂实测数据3 个角度对 n 型 TOPCon 光伏组件的弱光性能进行了分析;最后基于实际工程项目分析了弱光性能对系统PR的影响,揭示了n型TOPCon光伏组件PAN 文件(PVsyst软件中的光伏组件参数文件)参数失真问题对系统 PR 预测的影响规律,并提出了建议.研究结果表明:1)在单二极管等效电路模型中,并联电阻是主导 n 型 TOPCon 光伏组件弱光性能的电学参数.并联电阻越大,光伏组件的弱光性能越优异.2)当前市场主流n型TOPCon 光伏组件在太阳辐照度为200 W/m2 的弱光工况下的弱光损失率普遍分布在3%~5%区间,可作为行业参考基准.3)部分光伏组件制造商提供的PAN 文件,在拟合过程中采用过度理想化的参数,导致通过PVsyst软件仿真得到的系统PR预测结果偏高.在以系统PR为核心考核指标的严苛工程合同约束下,此类偏差可能使项目在验收阶段面临巨额性能罚款,甚至整体被拒收的重大履约风险.4)基于实测数据提出了 PAN 文件关键参数的合理取值范围,并给出了风险防控机制建议,为光伏发电项目实施提供了可靠的技术依据.
With the global scale application of n-TOPCon PV modules,their low-irradiance performance has become one of the key factors affecting the system performance ratio(PR),which will significantly affect the energy output of PV power generation systems under actual operating conditions.This paper first analyzes the evaluation indicators and key influencing factors of the low-irradiance performance of PV modules.Then,by comparing multiple sources of measured data,the low-irradiance performance of n-TOPCon PV modules is analyzed from three perspectives:public document data from mainstream PV module manufacturers,measured data from third-party testing agencies,and factory measured data from PV module manufacturers.Finally,based on actual engineering projects,the impact of low-irradiance performance on system PR is analyzed,revealing the influence of parameter distortion in the PAN file(PV module parameter file in PVsyst software)of n-TOPCon PV modules on system PR prediction,and proposing suggestions.The research results show that:1)In the equivalent circuit model of a single diode,parallel resistance is the dominant electrical parameter for the low-irradiance performance of n-TOPCon PV modules.The larger the parallel resistance,the better the low-irradiance performance of the PV module.2)The low-irradiance loss rate of mainstream n-TOPCon PV modules in the current market is generally distributed in the range of 3%to 5%under low-irradiance conditions with a solar irradiance of 200 W/m2,which can be used as an industry reference benchmark.3)Some PV module manufacturers use overly idealized parameters in the fitting process of PAN files,resulting in higher system PR prediction results obtained through PVsyst software simulation.Under the strict engineering contract constraints with system PR as the core assessment indicator,such deviations may result in significant performance fines during the acceptance stage of the project,or even a major performance risk of overall rejection.4)Based on measured data,a reasonable range of key parameters for PAN files is proposed,and suggestions for risk prevention and control mechanisms are provided,providing a reliable technical basis for the implementation of PV power generation projects.
刘延林;廖赛;郭金忠
中国电力工程顾问集团西南电力设计院有限公司,成都 610057中国电力工程顾问集团西南电力设计院有限公司,成都 610057中电国际技术股份有限公司,北京 100102
信息技术与安全科学
n型TOPCon光伏组件弱光性能PAN文件并联电阻弱光工况太阳辐照度能效比光伏发电仿真风险管控
n-TOPCon PV moduleslow-irradiance performancePAN fileparallel resistancelow-irradiance conditionssolar irradiancePRPV power generation simulationrisk management and control
《太阳能》 2026 (8)
77-84,8
评论