针对硬梁包水电站3、4号机组,分析了蜗壳进口压力对负荷调整过程中负荷到位程度的影响.研究发现,负荷稳定滞后于指令,其振荡与蜗壳进口压力动态变化密切相关,如长龙山抽水蓄能电站4号机组在甩负荷试验中,蜗壳压力变化值等数据显示其受蜗壳进口压力影响整体更突出[1],从零加负荷时,负荷响应滞后、超调明显;减负荷至零后,蜗壳进口压力波动随时间减弱.蜗壳进口压力波动是影响负荷到位程度的关键因素,如一管多机相继甩负荷时,蜗壳末端压力波动会影响机组运行.该结论为优化调速器PID参数、加强压力实时监测、调整导叶开度变化速率以提升负荷响应品质提供了依据,也为同类机组优化提供了参考.

This paper analyzes the impact of volute inlet pressure on the load attainment level during the load regulation of Units 3 and 4 of Yingliangbao Hydropower Station.The findings reveal that load lags behind the command signals,with oscillations closely correlated to dynamic variations in volute inlet pressure.For in-stance,data from Unit 4 at Changlongshan Pumped Storage Power Station during load rejection tests demon-strated pronounced sensitivity to volute inlet pressure[1]:load response exhibited significant lag and overshoot during initial loading,while pressure fluctuations at the volute inlet diminished over time after load reduction to zero.Volute inlet pressure fluctuations are a critical factor affecting load attainment;when multiple units un-dergo sequential load rejection through a single pipeline,pressure variations at the volute outlet can impair op-erational performance.These conclusions provide evidence for optimizing PID controller parameters,enhancing real-time pressure monitoring,and adjusting guide vane opening rates to improve load response quality,offering valuable insights for optimizing similar power units.

姜虹志;吕世杰;王小龙;陈力;赖星

四川华能泸定水电有限公司,四川 甘孜 626100四川华能泸定水电有限公司,四川 甘孜 626100四川华能泸定水电有限公司,四川 甘孜 626100四川华能泸定水电有限公司,四川 甘孜 626100四川华能泸定水电有限公司,四川 甘孜 626100

信息技术与安全科学

蜗壳进口压力负荷到位程度压力波动导叶开度

volute inlet pressureload attainment levelpressure fluctuationguide vane opening degree

《四川水力发电》 2026 (4)

111-115,5

10.20196/j.cnki.scslfd.20260423

评论