基于COMSOL的高纯氢氟酸中痕量As3+氧化脱除模拟OA
COMSOL-based simulation of oxidative removal of trace amounts of As3+from hydrofluoric acid
高纯氢氟酸作为半导体与电子信息行业的关键原料,其绿色高效除杂工艺的开发因具有重要意义而受到广泛关注.目前高纯氢氟酸除As3+的方法存在易引入杂质、难以连续操作及成本较高等问题.针对现有技术的不足,文中采用F2/N2的混合气体作为氧化剂,将痕量As3+杂质氧化成AsF5,利用AsF5与氢氟酸挥发度的差异实现分离.基于COMSOL软件构建氧化塔的数值模型,模拟不同氧化塔结构与工况条件下F2/N2对 As3+的氧化去除效果.模拟结果表明:当液体入口 As3+质量分数为5 ×10-6、F2/N2摩尔比为0.2、气体流速为60 L/h且氧化塔内部添加错落排列的半圆形挡板时,As3+的氧化效果最佳,液体出口处As3+浓度最低,达4.303 4 × 10-11 mol/m3.此研究为高纯氢氟酸连续除砷工艺的开发提供了理论支撑.
An efficient and environmentally friendly purification process for high-purity HF(hydrofluoric)acid,a critical raw material in the semiconductor and electronics industries,is developed.Existing methods for removing As3+impurities face challenges such as secondary contamination,discontinuous operation,and high costs.To address these limitations,a F2/N2 mixed gas was employed as an oxidizing agent to convert trace As3+into volatile AsF5,and separation was achieved based on the differences in volatility between AsF5 and hydrofluoric acid.A numerical model of the oxidation tower was developed in COMSOL to evaluate the effects of tower geometry and operational parameters on As3+removal efficiency.The results demonstrate that optimal performance is achieved under the following conditions:an inlet As3+mass fraction of 5 × 10-6,F2/N2 molar ratio of 0.2,gas flow rate of 60 L/h,and the use of staggered semi-circular baffles.Under these optimized parameters,the outlet As3+concentration is reduced to 4.303 4 × 10-11 mol/m3.This work provides a theoretical foundation for implementing continuous arsenic removal in high-purity HF production.
戴雪凡;郭其景;杨华春;刘海霞;薛峰峰;易浩;宋少先
武汉理工大学资源与环境工程学院,湖北武汉 430070武汉理工大学资源与环境工程学院,湖北武汉 430070多氟多新材料股份有限公司,河南焦作 454006多氟多新材料股份有限公司,河南焦作 454006多氟多新材料股份有限公司,河南焦作 454006武汉理工大学资源与环境工程学院,湖北武汉 430070武汉理工大学资源与环境工程学院,湖北武汉 430070
化学化工
高纯氢氟酸数值模拟痕量As3+除杂结构优化最优工况
high-purity hydrofluoric acidnumerical simulationtrace As3+decontaminationstructural optimizationoptimal operating conditions
《化学工程》 2026 (8)
30-36,7
国家重点研发计划项目(2022YFC2904805)
评论