以地源热泵为核心的复合能源系统优化运行策略研究OA
Research on the optimal operation strategy of a composite energy system centered on ground source heat pumps
针对以地源热泵为核心并耦合冷水机组、水蓄能装置及蓄热式电锅炉的复合冷热源系统,以运行费用最低和运行能耗最低为双优化目标,建立"谷电蓄能、峰电释能"费用优化调度模型与土壤热平衡-设备变流量能耗优化模型,并以雄安新区某科创园区为研究对象进行动态仿真,对比分析无蓄能常规运行、简单蓄能固定时段运行及优化动态蓄释能共3种策略.结果表明,费用优化策略充分利用峰谷电价差,全年运行费用降低21.4%;能耗优化策略通过地温场主动调控、出水温度动态优化及变流量精准控制,全年能耗降低11.8%,系统综合能效比由4.23提升至4.80,土壤温度年波动控制在±2.6℃以内,25年运行地源侧水温维持在11.9~24.0℃;费用优化策略因蓄能效率损失导致总能耗增加4.7%,能耗优化策略牺牲了部分经济性.
For the composite cold and heat source system centered on ground source heat pumps and coupled with chiller units,water storage devices,and heat storage electric boilers,with the dual optimization goals of the lowest operating cost and the lowest operating energy consumption,an'energy storage during off-peak hours and energy release during peak hours'cost optimization scheduling model and a soil heat balance-equipment variable flow energy consumption optimization model are established.Taking a certain science and technology innovation park in Xiongan New Area as the research object,a dynamic simulation is conducted,and three strategies including conventional operation without energy storage,simple energy storage operation in fixed periods,and optimized dynamic energy storage and release are compared and analyzed.The results show that the cost optimization strategy fully utilizes the price difference between off-peak and peak hours,reducing the annual operating cost by 21.4%.The energy consumption optimization strategy,through active regulation of the ground temperature field,dynamic optimization of the outlet water temperature,and precise control of variable flow,reduces the annual energy consumption by 11.8%,and the system's comprehensive energy efficiency ratio increases from 4.23 to 4.80.The soil temperature fluctuation is controlled within±2.6℃throughout the year,and the water temperature on the ground source side remains between 11.9℃and 24.0℃for 25 years of operation.The cost optimization strategy leads to an increase in total energy consumption of 4.7%due to the loss of energy storage efficiency,while the energy consumption optimization strategy sacrifices some economic benefits.
边争
同济大学建筑设计研究院(集团)有限公司,上海 200092
建筑与水利
地源热泵复合能源系统水蓄能土壤热平衡
ground source heat pumpcomposite energy systemwater storagesoil heat balance
《节能》 2026 (7)
53-57,5
评论