某火电厂高温高压蒸汽管道声流耦合共振分析及处理OA
Analysis and Treatment of Acoustic Flow Coupling Resonance in High Temperature and High Pressure Steam Pipeline of a Thermal Power Plant
某1 000 MW火电机组自建成投产以来高压旁路阀附近的主蒸汽-高压旁路蒸汽管道就存在显著的高频低幅振动,并伴有强烈的汽流噪声,通过现场振动测试明确管道振源位置位于高压旁路三通支管区域,并发现该管道振动呈现显著的单峰频率特征,且管道振动频率随机组负荷变化不大,综合利用声流耦合共振理论分析、现场高压旁路阀启闭验证试验、有限元仿真模拟计算等手段明确了管道振动的根本原因就是声流耦合共振,并最终通过缩短旁支管长度的方案有效解决了现场振动故障,成为火电行业首次发现并成功解决的声流耦合共振案例,为后续类似故障的分析与处理提供了参考.
Addressing the long-standing issue of high-frequency low-amplitude vibration and intense airflow noise in the main steam-to-high-pressure bypass steam piping of a 1 000 MW thermal power unit,on-site tests were conducted to locate the vibration source in the tee-branch pipe area of the high-pressure bypass.The tests confirmed that the vibration exhibited a pronounced single-peak frequency characteristic and was minimally affected by unit load.By comprehensively applying the acoustic-flow coupled resonance theory,on-site open/close tests of the high-pressure bypass valve,and finite element simulation calculations,the root cause of the piping vibration was identified as acoustic-flow coupled resonance.Ultimately,a mitigation measure involving shortening the length of the bypass branch pipe was implemented,which effectively eliminated the piping vibration fault.This case represents the first successful identification and resolution of such a resonance issue in the thermal power industry,providing an important reference for the analysis and handling of similar faults in the future.
李泽;马记;刘明;李日照;刘炳广
华电电力科学研究院有限公司,浙江 杭州 310030华电莱州发电有限公司,山东莱州 261400华电电力科学研究院有限公司,浙江 杭州 310030华电电力科学研究院有限公司,浙江 杭州 310030华电莱州发电有限公司,山东莱州 261400
能源科技
声流耦合流致声共振声模态谐振腔高压旁路管道高压旁路阀
acoustic flow couplingflow-induced acoustic resonanceacoustic moderesonant cavityhigh-pressure bypass pipelineshigh-pressure bypass valve
《锅炉技术》 2026 (4)
68-73,6
华电集团科技项目(CHDKJ22-02-56)
评论