1000MPa级高强钢配套焊材水电焊接模型水压试验验证及可靠性评估OA
Verification and Reliability Assessment of Hydraulic Welding Models Us-ing Welding Materials Compatible with 1 000 MPa-grade High-strength Steel for Hydrostatic Testing
为验证1 000 MPa级水电用高强钢配套焊材在压力钢管焊接结构中的适用性和可靠性,设计并制造了两套局部缩比压力钢管焊接模拟件并开展水压试验.1#模拟件纵缝及环缝分别采用国产和进口1 000 MPa级气体保护焊丝,在9.5 MPa峰值压力下监测关键焊缝区域的结构应力分布与承载响应;2#模拟件纵缝采用国产1 000 MPa级埋弧焊丝/焊剂,环缝采用国产1 000 MPa级手工电弧焊条和600 MPa级气体保护焊丝,峰值压力10.25 MPa,同步测试水压试验前后焊接残余应力并监测结构位移.结果表明:1#模拟件实测最大结构应力为175.8 MPa,低于运行和水压试验工况下的许用应力,卸压后UT与TOFD复检未发现超标缺陷;2#模拟件在10.25 MPa下内壁和外壁最大结构应力分别为348.9 MPa和260.5 MPa,主要测点应力和位移随压力变化呈较好的线性关系,卸压后复检未见线性缺陷;水压试验后焊接残余应力总体降低并发生重分布,内壁σx 和σy 方向平均消除率分别为26.6%和36.6%,外壁分别为27.9%和33.3%.研究表明,在本文模拟件结构、焊接工艺和水压试验条件下,所选国产配套焊材及工艺可满足1 000 MPa级水电用高强钢压力钢管焊接结构的水压验证要求.
Hydraulic proof testing is a critical validation procedure for ensuring the structural integrity of welded penstock joints in hydropower stations.However,systematic experimental data remain limited regarding welded joints employing do-mestic welding consumables for 1000 MPa-grade high-strength steels.Two locally scaled cylindrical penstock mock-ups were designed and fabricated to evaluate the applicability of domestic welding consumables.The No.1 mock-up utilized do-mestic and imported 1000 MPa-grade gas metal arc welding(GMAW)wires for the longitudinal and circumferential seams,respectively,and was pressurized to 9.5 MPa.Strain gauges installed at critical weld locations recorded structural stress dis-tributions under loading.The second mock-up employed domestic 1000 MPa-grade submerged arc welding(SAW)wire/flux and 1000 MPa-grade shielded metal arc welding(SMAW)electrodes for different seams,and was pressurized to 10.25 MPa.Residual stresses were measured before and after testing,and structural displacements were monitored.Results indicate that for the No.1 mock-up,the stress-pressure relationships at all gauge locations were linear(R2≥0.99),with the maximum measured structural stress of 175.8 MPa well below the allowable stress limits for both operating and proof test conditions;no unacceptable defect indications were detected by UT and TOFD re-inspection after unloading.For the No.2 mock-up,the maximum structural stresses at 10.25 MPa were 348.9 MPa(inner wall)and 260.5 MPa(outer wall),both stress and dis-placement exhibited proportional responses to pressure,and no linear defects were found upon post-test re-inspection.Post-test welding residual stresses decreased notably,with average relief rates of 26.6%-36.6%on the inner wall and 27.9%-33.3%on the outer wall.The findings suggest that the selected domestic welding consumables and procedures can satisfy the hydraulic proof testing requirements for 1000 MPa-grade high-strength steel penstock welded structures within the scope of the mock-up configurations and test conditions presented.
惠振国;田野;田井成;甘洪丰;卢天田;吴海龙
哈尔滨电机厂有限责任公司,黑龙江 哈尔滨 150040哈尔滨电机厂有限责任公司,黑龙江 哈尔滨 150040哈尔滨电机厂有限责任公司,黑龙江 哈尔滨 150040哈尔滨电机厂有限责任公司,黑龙江 哈尔滨 150040哈尔滨电机厂有限责任公司,黑龙江 哈尔滨 150040哈尔滨电机厂有限责任公司,黑龙江 哈尔滨 150040
能源科技
1000MPa级水电用高强钢焊接材料压力钢管结构应力焊接残余应力
hydrostatic test1000 MPa-grade high-strength steel for hydropowerwelding consumablespenstockstructural stresswelding residual stress
《电焊机》 2026 (8)
105-115,11
黑龙江省重点研发计划项目(2022ZX04A01)黑龙江省自然科学基金资助项目(YQ2021E007)
评论