首页|期刊导航|电气传动|电网不平衡工况下链式储能变流器SOC均衡控制方法研究

电网不平衡工况下链式储能变流器SOC均衡控制方法研究OA

Research on SOC Balancing Control Method for Cascaded Energy Storage Converters Under Grid Unbalanced Conditions

中文摘要英文摘要

在电网电压不平衡工况下,链式储能变流器三相之间会产生有功功率偏差,进而会使得三相荷电状态(SOC)失衡,最终会降低容量利用率和系统可靠性.针对该问题提出了一种负序电流和零序电压混合注入的控制策略,当单独采用零序电压注入无法实现相间SOC均衡时,剩余的功率偏差可以通过负序电流注入来均衡,这样既避免了所需注入零序电压过高导致输出电压畸变的问题,相较于单独负序电流注入,也减小了流向电网的负序电流,该控制策略兼顾了相间SOC均衡能力及变流器输出电能质量.最后通过仿真验证了该均衡控制方案的有效性.

Under grid voltage unbalance conditions,active power deviations occur between the three phases of the cascaded energy storage converter,leading to unbalanced three-phase state of charge(SOC)and ultimately reducing capacity utilization and system reliability.To address this issue,a control strategy based on the hybrid injection of negative-sequence current and zero-sequence voltage was proposed.When zero-sequence voltage injection alone cannot achieve SOC balance,the remaining power deviation was balanced through negative-sequence current injection.This approach avoids the issue of excessive zero-sequence voltage injection causing output voltage distortion,and compares to using negative-sequence current injection alone,it also reduces the negative-sequence current flowing into the grid.This control strategy balances both phase-to-phase SOC balancing capability and the output power quality of the converter.Finally,the effectiveness of this approach was verified through simulation.

李志鹏;李嘉豪;王军;郑毅;王丽;何英杰

河南许继仪表有限公司,河南 许昌 461000西安交通大学 电气工程学院,陕西 西安 710049河南许继仪表有限公司,河南 许昌 461000河南许继仪表有限公司,河南 许昌 461000河南许继仪表有限公司,河南 许昌 461000西安交通大学 电气工程学院,陕西 西安 710049

信息技术与安全科学

链式储能变流器负序电流注入零序电压注入荷电状态

cascaded energy storage convertersnegative-sequence current injectionzero-sequence voltage injectionstate of charge(SOC)

《电气传动》 2026 (8)

13-20,8

10.19457/j.1001-2095.dqcd26630

评论