多场耦合下栅片特性对直流空气电弧开断性能影响OA
Investigating the Influence of Splitter Characteristics on DC Air Arc Interruption in a Multi-Physics Coupling Environment
直流空气断路器利用磁场将电弧吹入金属栅片切割完成分断.金属栅片间隙窄,电弧烧蚀产生的金属蒸气不易扩散,同时,栅片近极压降、导磁特性都会影响电弧的熄灭时间.该文考虑了铜、铁、钢三种栅片材料电弧与金属蒸气的耦合作用,在电弧磁流体动力学(MHD)模型中加入物质传递方程,将电弧的电磁场、气流场、温度场及扩散金属蒸气相互耦合,仿真分析多因素共同作用下,电弧在灭弧室内的运动行为及能量变化引起的开断过程.并通过实验对比,验证仿真结果.研究结果表明,金属栅片材料对电弧演化过程产生了显著影响.铜栅片更容易释放金属蒸气,抑制了电弧的有效拉伸,近极压降无法快速建立,不利于熄弧.铁栅片的磁导率高、抗烧蚀能力强,但易在栅片入口处发生磁短路,造成电弧运动的局部停滞,加速栅片入口处金属蒸气堆积.不导磁的钢栅片,兼具抗烧蚀能力和磁驱特性,表现出更优的电弧开断性能.
The interruption process in a DC air circuit breaker relies on magnetically driving the arc into metallic splitter plates.With the ongoing trend towards miniaturization,the internal structure of breakers has become increasingly compact.Such compactness poses a challenge:during fault current interruption,metal vapor generated by ablation of the splitter plates tends to accumulate locally and dissipate poorly,thereby altering plasma properties and compromising arc-interruption efficiency.Arc interruption is fundamentally a competition between heat generation,determined by arc power,and heat dissipation.Two key factors influence heat dissipation.First,the magnetic field affects arc length,driving velocity,and the establishment of near-electrode voltage drops by altering arc force distribution and airflow patterns,thereby determining the rate of rise of the arc voltage.Second,the metal vapor from arc ablation modifies the heat-transfer and electrical-conductivity characteristics of the gas within the arc chamber,thereby influencing the evolution of the arc temperature field and the ultimate arc extinction time.Thus,the interruption performance is co-determined by magnetic field behavior and metal vapor transport.Crucially,the permeability and melting point of the splitter plate material directly affect magnetic blow strength and vapor dissipation,playing a pivotal regulatory role in the arc interruption process. Based on this understanding,this paper selects various splitter plate materials and establishes a bidirectional coupling model that integrates arc ablation and metal vapor diffusion.The influence of different materials on energy transfer and field distribution during arc extinction is analyzed.A mass concentration equation is incorporated into the traditional magneto hydro dynamic(MHD)arc-interruption model to describe the convective and diffusive behavior of metal vapor generated by plate ablation.Accordingly,bidirectional coupling between the arc plasma and vapor transport is achieved.The dynamic diffusion of metal vapor within the arc chamber and the associated changes in multiple physical fields are simulated.An experimental platform was constructed based on an actual product. The following conclusions can be drawn from simulations and experiments.(1)Metal vapor from arc ablation of the plates increases the temperature inside the arc chamber.It readily accumulates in narrow gaps,increasing plasma conductivity,hindering the formation of the near-electrode voltage drop,prolonging arc extinction time,and thus reducing interruption speed.(2)Iron splitter plates exhibit higher ablation resistance;however,their high magnetic permeability induces magnetic flux concentration and local magnetic short-circuiting,which weakens the magnetic blow force between plates.It causes the arc to stagnate at the plate entrance,exacerbating vapor accumulation.(3)Copper splitter plates,due to their lower melting point,tend to generate substantial metal vapor,which impedes arc stretching.In contrast,non-magnetic steel splitter plates avoid magnetic short-circuiting while maintaining considerable ablation resistance,demonstrating superior interruption characteristics.
李静;张龙豪;段薇;马骋昊;付思
沈阳工业大学电气工程学院特种电机与高压电器教育部重点实验室 沈阳 110870沈阳工业大学电气工程学院特种电机与高压电器教育部重点实验室 沈阳 110870沈阳工业大学电气工程学院特种电机与高压电器教育部重点实验室 沈阳 110870沈阳工业大学电气工程学院特种电机与高压电器教育部重点实验室 沈阳 110870沈阳工业大学电气工程学院特种电机与高压电器教育部重点实验室 沈阳 110870
信息技术与安全科学
直流空气断路器金属栅片金属蒸气磁流体力学电弧开断
DC air circuit breakermetal splitter platesmetallic vapormagneto hydro dynamicarc interruption
《电工技术学报》 2026 (16)
5651-5662,12
国家自然科学基金(51407120)和辽宁省科技计划联合计划(自然科学基金-面上项目)(2024-MSLH-366)资助.