针对现有主网雷害风险评估方法在配电网中适用性不足的问题,提出一种考虑多影响因素的10 kV配电网雷害风险动态评估方法.该方法综合考虑线路参数、建筑物分布、地表水体、土壤类型、雷电地闪密度与雷电流幅值分布等多源因素,建立涵盖直击雷、感应雷及建筑物屏蔽修正的完整雷击闪络率计算体系.引入深度学习语义分割模型,基于高分辨率遥感影像自动提取建筑物轮廓与地表水体信息,实现地理参数的动态更新;结合雷电定位系统数据,动态获取雷电活动参数,支撑区域风险的动态评估.采用1 km × 1 km网格划分与极差归一化方法,生成区域雷害风险分布图.以北京地区为案例开展实证应用,在怀柔、密云、平谷三区验证了该方法能够有效反映区域雷害风险的真实分布特征.该方法为10 kV配电网差异化防雷规划与运维管理提供了系统性的理论依据和实用工具.

To address the limited applicability of existing lightning risk assessment methods for transmis-sion networks in distribution networks,the author proposes a dynamic lightning risk assessment method considering multiple influencing factors for 10 kV distribution networks.The method comprehensively in-tegrates multiple influencing factors,including line parameters,building distribution,surface water bodies,soil types,lightning ground flash density,and lightning current amplitude distribution.A com-prehensive calculation system for lightning flashover rates is established,encompassing direct lightning strikes,induced lightning overvoltages,and building shielding corrections.A deep learning-based se-mantic segmentation model is adopted to automatically extract building outlines and surface water informa-tion from high-resolution remote sensing imagery,enabling the dynamic update of geographical parame-ters.Combined with the monitoring data of lightning location systems,lightning activity parameters are acquired in real-time to support the dynamic assessment of regional risks.Using a 1 km × 1 km grid di-vision and range normalization,regional lightning risk maps are generated.An empirical application was conducted in the Beijing area as a case study.The results obtained in the Huairou,Miyun,and Pinggu districts verify that the proposed method can effectively reflect the actual distribution characteristics of re-gional lightning risks.This approach provides a systematic theoretical basis and a practical tool for differ-entiated lightning protection planning and operation and maintenance management of 10 kV distribution networks.

齐帅;彭玉宾;张佳辉;雷挺;沈海滨;赵霞;章超;谢毅铭

国网北京市电力公司,北京 100031国网北京市电力公司,北京 100031国网北京市电力公司,北京 100031中国电力科学研究院有限公司,北京 100192中国电力科学研究院有限公司,北京 100192中国电力科学研究院有限公司,北京 100192国网北京市电力公司,北京 100031国网北京市电力公司,北京 100031

配电网10kV架空线路雷害风险评估雷击闪络率感应雷建筑物屏蔽深度学习动态评估

distribution network10 kV overhead linelightning hazard risk assessmentlightning stroke flashover rateindirect lightningbuilding shieldingdeep learningdynamic assessment

《电瓷避雷器》 2026 (4)

10-19,10

国网北京市电力公司科技项目资助(编号:520214240001).Project supported by the Science and Technology Project of State Grid Beijing Electric Power Company(No.520214240001).

10.16188/j.isa.1003-8337.2026.04.002