Overview of Common-mode Noise Cancellation Techniques for Isolated Power ConvertersOA
With the application of wide-bandgap devices and planar transformers in isolated power converters,the converters exhibit high dv/dt and large parasitic capacitance,and severe common-mode(CM)noise is generated.As a general approach to attenuating the CM noise,passive CM electromagnetic interference(EMI)filters occupy a considerable volume and weight of the system.Therefore,various CM noise cancellation techniques have been proposed to reduce the size of CM EMI filters.In this overview,four basic groups of CM noise cancellation techniques are reviewed:(1)reduction of CM parasitic capacitance,(2)adjustment of the transformer winding structure,(3)optimization of circuit configuration,and(4)addition of cancellation circuits.The advantages,disadvantages,and relationships between these techniques are systematically summarized,and future work is discussed.
Lihong Xie
College of Automation,Nanjing University of Aeronautics and Astronautics,Nanjing 211106,China
信息技术与安全科学
Isolated power converterscommon-mode noisenoise cancellation techniquesEMI filterwide-bandgap devices
《Chinese Journal of Electrical Engineering》 2026 (2)
P.66-82,17
Supported by the National Natural Science Foundation of China(52507224)the Natural Science Foundation of Jiangsu Province(BK20241416)Delta Power Electronics Science and Technology Educational Development Program of Delta Group(DREG2025002).