Faulty-line Selection Method Based on Pearson Correlation Coefficient in Neutral Non-effectively Grounded SystemsOA

中文摘要

When a single-phase grounded fault occurs in a distribution network,a quick selection of the faulty line is crucial for the safe and reliable operation of the network.To address the low accuracy of selection devices in detecting grounded faulty lines,a line selection method based on the Pearson correlation coefficient is proposed by analyzing the similarity of the zero-sequence current fitting curve and the slope curve of each line in the distribution network when a single-phase grounded fault occurs.The apparent difference between the slope of the zero-sequence current fitting curve of the faulty and healthy lines is used to select the faulty line.Specifically,a local weighted linear fitting and differentiation are performed on the zero-sequence currents of each line to obtain the corresponding slope curves.Subsequently,the similarity of the slope curves of the zero-sequence current waveforms of the adjacent lines is used to determine the faulty line.If the similarity between a line and two adjacent lines is poor or negative(Pearson correlation coefficient close to or less than 0),it is determined as a faulty line.If the similarity between a line and at least one adjacent line is high(Pearson correlation coefficient close to 1),it is determined to be a healthy line.If the similarity of the slope curves of the zero-sequence current waveform of all lines is high(Pearson correlation coefficient close to 1),it is determined to be a bus fault.Matlab/Simulink simulation results showed that the proposed method is effective under various fault conditions and has a high detection sensitivity to high transition resistance faults.

Yang Lei;Fan Yang;Yinjun Zhu;Jun Wang;Liuxin Xie;Jinghua Wang;Chao Wang;Heng Chen

State Grid Hubei Electric Power Company Electric Power Research Institute,Wuhan 430077,ChinaState Grid Hubei Electric Power Company Electric Power Research Institute,Wuhan 430077,ChinaState Grid Hubei Shennongjia Power Supply Company,Shennongjia 442400,ChinaState Grid Hubei Shennongjia Power Supply Company,Shennongjia 442400,ChinaState Grid Hubei Electric Power Company Electric Power Research Institute,Wuhan 430077,ChinaShandong Kehui Power Automation Company,Zibo 255000,ChinaShandong Kehui Power Automation Company,Zibo 255000,ChinaShandong Kehui Power Automation Company,Zibo 255000,China

信息技术与安全科学

Single-phase grounded faultslope curvePearson correlation coefficientfaulty-line selection

《Chinese Journal of Electrical Engineering》 2026 (2)

P.299-310,12

Supported the by State Grid Hubei Electric Power Company Technology Project(B3153221001K).

10.23919/CJEE.2026.000005