首页|期刊导航|灾害学|城市特长隧道带散排口的分段纵向排烟模式排烟性能研究

城市特长隧道带散排口的分段纵向排烟模式排烟性能研究OA

Study on Smoke Exhaust Performance of Segmented Longitudinal Smoke Exhaust Mode with Dispersed Exhaust Outlets in Urban Extra-long Tunnels

中文摘要英文摘要

为了研究城市特长隧道散排口排烟模式下的排烟性能,该文分析了隧道纵向温度衰减规律、散排口处流场、温度场规律及排热效率.结果表明:随着火源热释放速率增大,散排口排热量增加,但对烟气的控制效果更差.随着纵向风速增大,烟气蔓延速度加快,顶板下最大温升减小,但过大的纵向风速不利于散排口对烟气的控制;增大排烟量可提升烟气控制效果,但导致下游散排口利用率降低.根据散排口的排热效率不受火源热释放速率和纵向风速的影响,只随着排烟量增大而提高,提出了与无量纲排烟量相关的散排口排烟效率预测模型.在实际工程中,散排口的排热效率随排烟量变化存在边际效应,应选取合理的排烟量进行设计.

To investigate the smoke exhaust performance of the dispersed exhaust mode in urban extra-long tunnels,longitudinal temperature decay patterns,the flow and temperature field characteristics at the dispersed ex-haust outlets,and the heat exhaust efficiency under varying heat release rates,longitudinal velocities,and exhaust volumes are analyzed in this study.The results show that as the heat release rate increases,the amount of high-temperature smoke generated within the tunnel grows,leading to greater heat exhaust through the outlets;howev-er,this results in poorer smoke control and higher overall temperatures inside the tunnel.As the longitudinal ve-locity increases,smoke spread accelerates,and the maximum temperature rise beneath the ceiling decreases,but excessively high longitudinal velocities impair smoke control via the dispersed exhaust outlets.Increasing the ex-haust volume raises the heat exhaust through the outlets and lowers the downstream temperatures.Although larg-er exhaust volumes improve smoke control,they reduce the utilization rate of the downstream outlets,causing wasted exhaust capacity.The heat exhaust efficiency of the dispersed exhaust outlets is nearly independent of the heat release rate and the longitudinal velocity,but increases with the exhaust volume.Based on this finding,a prediction model for the exhaust efficiency of the dispersed exhaust outlets,correlated with the dimensionless ex-haust volume,is proposed.In practical engineering,the heat exhaust efficiency exhibits a marginal effect as the exhaust volume varies;therefore,a reasonable exhaust volume should be selected in design.

梁志雯;方忠强;孙统立;岳犇;于子涵;封世林;徐志胜

江苏省交通工程建设局,江苏 南京 210004华设设计集团股份有限公司,江苏 南京 210004华设设计集团股份有限公司,江苏 南京 210004华设设计集团股份有限公司,江苏 南京 210004中南大学 防灾科学与安全技术研究所,湖南 长沙 410075中南大学 防灾科学与安全技术研究所,湖南 长沙 410075中南大学 防灾科学与安全技术研究所,湖南 长沙 410075

资源环境

隧道火灾散排口分段纵向排烟排烟效率

tunnel firedispersed exhaust outletssegmented longitudinal smoke exhaustsmoke exhaust efficiency

《灾害学》 2026 (4)

73-83,11

苏通第二过江通道工程"城市建成区长隧道消防安全与防灾救援关键技术研究"(STE-ZT-3-11)

10.3969/j.issn.1000-811X.2026.04.008