发电机定子绕组的局部放电检测有助于反映电机绝缘状况,保障发电机安全运行.传统的脉冲电流法在现场使用中极易受电磁干扰且无法反映定子绕组局部放电的位置,而光纤传感采用全绝缘结构,抗电磁干扰且容易内置,在局部放电检测中具有较高的应用潜力.因此,提出一种基于光纤传感的定子线棒局放检测方法,对传感单元进行了优化设计并测试相关性能,通过仿真和试验研究其对于线棒端部电场的影响.在此基础上,搭建发电机定子线棒局部放电检测试验平台,在不同缺陷的定子线棒上开展试验.结果表明:所设计的光纤超声传感系统对于定子线棒局部放电具有较好的检测效果,能够检测到30 pC的内部缺陷放电,对于3种不同表面缺陷引发的放电,其最低可测放电量为20 pC,且均能在放电量60 pC以下时检测到有效信号,明显优于传统的压电传感器;不同缺陷类型超声信号的峰值频段具有一致性,但各频段分量具有明显差异.

Partial discharge detection of generator stator winding helps to reflect the insulation condition of a motor and ensure the safe operation of a generator.The traditional pulse current method is susceptible to electromagnetic interfer-ence and cannot reflect the location of partial discharge in the stator winding in the field,while the fiber optic sensing adopts a fully insulated structure,which is resistant to electromagnetic interference and easy to be built-in,and has a high potential for application in partial discharge monitoring.Therefore,a detection method based on Michelson interference is proposed for stator bars,the sensing unit is optimized and tested,and its effect on the electric field at the end of the bars is investigated through simulation and experiment.On this basis,a test platform for partial discharge detection of generator stator bars is built,and tests are carried out on stator bars with different defects.The results show that the designed fi-ber-optic ultrasonic sensing system has a good detection effect on partial discharge at the stator bar end.The designed fiber optic ultrasonic sensing system has a good detection effect on the partial discharge of stator bars,and can detect the internal defect discharge of 30 pC.For discharges caused by three different surface defects,the lowest measurable dis-charge amount is 20 pC,and effective signals can be detected below a discharge amount of 60 pC,which is significantly better than traditional piezoelectric sensors.The peak frequency bands of ultrasonic signals of different defect types are consistent,but the components of each frequency band have obvious differences.

胡建林;秦培宇;宋展;刘怡杰;曾维毅;蒋兴良

重庆大学雪峰山能源装备安全国家野外科学观测研究站,重庆 400044重庆大学雪峰山能源装备安全国家野外科学观测研究站,重庆 400044重庆大学雪峰山能源装备安全国家野外科学观测研究站,重庆 400044重庆大学雪峰山能源装备安全国家野外科学观测研究站,重庆 400044重庆大学雪峰山能源装备安全国家野外科学观测研究站,重庆 400044重庆大学雪峰山能源装备安全国家野外科学观测研究站,重庆 400044

定子线棒局部放电光纤超声传感频谱分析性能测试

stator barpartial dischargefiber optic ultrasonic sensingspectrum analysisperformance testing

《高电压技术》 2026 (7)

3277-3286,10

10.13336/j.1003-6520.hve.20241511

评论