首页|期刊导航|高电压技术|组串式光伏场站并网系统次同步振荡

组串式光伏场站并网系统次同步振荡OA

Sub-synchronous Oscillations in String-based Grid-connected Photovoltaic System

中文摘要英文摘要

组串式光伏与集中式光伏在拓扑结构与控制环节时间尺度方面存在较大差异,其并网稳定特性与集中式相比是否存在差异是值得研究的问题.该文基于组串式光伏电站典型拓扑,建立了光伏电站等值模型及其状态空间方程,通过特征模式分析和详细电磁暂态仿真研究了组串式光伏并网的次同步振荡问题.研究表明,尽管组串式光伏变流器电流控制环理论设计带宽远高于次超同步频段,但是在低短路比并网状态时电流控制回路主导的特征模式位于次同步频段且存在振荡风险;特征根灵敏度分析表明系统短路比和电流环控制参数对该模式稳定性具有重要影响,特征根轨迹分析揭示了运行工况和控制参数对该次同步振荡模式稳定性的影响规律,电磁暂态仿真验证了特征模式分析结果的正确性.通过频域特性分析发现并网系统短路比降低导致组串式光伏电流环控制回路带宽迅速降低至次/超同步振荡频段,存在与集中式光伏并网机理相似的次/超同步振荡风险.

String inverter-based photovoltaic systems differ substantially from centralized photovoltaic systems in terms of topology and control-loop time scales,and it is necessary to further investigate whether their grid-connected stability characteristics differ from those of centralized photovoltaic systems.To analyze the stability characteristics of string in-verter-based PV plants,this paper establishes an equivalent model and the corresponding state-space equations based on the typical topology of string PV stations.The subsynchronous oscillation problem of grid-connected string inverter-based photovoltaic systems is investigated through eigenmode analysis and detailed electromagnetic transient simulations.The results reveal that,although the theoretically designed bandwidth of string PV converter current control loops far exceeds the sub/super-synchronous frequency range,under low-short-circuit-ratio grid-connected conditions,the eigenmode dom-inated by the current control loop is located in the subsynchronous frequency band and presents oscillation risks.Eigenvalue sensitivity analysis demonstrates that the system short-circuit ratio and current-loop control parameters signif-icantly affect the stability of this mode.Eigenvalue trajectory analysis reveals how operational conditions and control parameters affect the stability of this subsynchronous oscillation mode.Electromagnetic transient simulations validate the accuracy of the eigenmode analysis results.Frequency-domain analysis shows that a decrease in the short-circuit ratio of the grid-connected system rapidly reduces the bandwidth of the current control loop in string photovoltaic systems to the sub-/super-synchronous oscillation frequency range,indicating that string photovoltaic systems may have sub-/super-synchronous oscillation risks similar to those of centralized grid-connected photovoltaic systems.

马望;孙冠群;陈雅欣;陈汝斯;蔡德福;孙海顺

国网湖北省电力有限公司电力科学研究院,武汉 430077国网湖北省电力有限公司电力科学研究院,武汉 430077华中科技大学电气与电子工程学院,武汉 430074国网湖北省电力有限公司电力科学研究院,武汉 430077国网湖北省电力有限公司电力科学研究院,武汉 430077华中科技大学电气与电子工程学院,武汉 430074

组串式光伏电流环控制特征模式分析次/超同步振荡短路比

string photovoltaiccurrent loop controleigenvalue analysissub/super-synchronous oscillationshort circuit ratio

《高电压技术》 2026 (7)

3197-3207,中插9,12

10.13336/j.1003-6520.hve.20251230