首页|期刊导航|电工技术学报|面向脉冲负载供电系统的传导电磁干扰机理与电磁安全评估

面向脉冲负载供电系统的传导电磁干扰机理与电磁安全评估OA

Conducted Electromagnetic Interference Mechanism and Electromagnetic Safety Assessment for Pulsed Power Load Power Supply Systems

中文摘要英文摘要

针对脉冲负载供电系统在复杂动态工况下易产生宽频带传导电磁干扰(EMI)的问题,该文围绕脉冲负载供电系统传导 EMI 形成机理及电磁安全特性开展研究.首先,以移相全桥变换器为研究对象建立脉冲负载供电系统差模传导干扰分析模型,分析脉冲负载动态特性对输入侧传导 EMI 频谱的影响机理;其次,基于多时间尺度分析方法,研究脉冲负载低频动态特性与变换器高频开关谐波之间的耦合作用,实验结果表明,脉冲负载会对输入电流高频开关谐波产生调制作用;最后,分析脉冲负载工况下输入电流振荡、电磁环境风险以及极端脉冲条件下的电磁安全裕度问题.研究结果表明,脉冲负载动态变化会导致输入侧 EMI 频谱复杂程度增加,并进一步提高供电系统局部谐振及动态失稳风险.

Pulsed power load supply systems operating under dynamic conditions generate more complicated conducted electromagnetic interference(EMI)than conventional steady-state converters because of the interaction between low-frequency pulse dynamics and high-frequency switching harmonics.Existing conducted EMI studies mainly focus on steady-state operating conditions,whereas the EMI formation mechanism and electromagnetic safety characteristics under pulse operating conditions remain insufficiently understood.This paper investigates the conducted EMI mechanism and electromagnetic safety assessment of pulse load power supply systems. A phase-shifted full-bridge converter was selected as the research object.First,a differential-mode conducted EMI analytical model was established by regarding the converter input current as the differential-mode noise source and incorporating the line impedance stabilization network(LISN)into the equivalent circuit.Subsequently,a multi-time-scale analytical framework was developed to describe the interaction between low-frequency pulse dynamics and high-frequency switching harmonics.The pulse load current was decomposed into DC and AC components,and an input current spectrum model was derived by linearizing the harmonic components around the operating point.The analytical results revealed that the low-frequency pulse current dynamically modulates the converter switching harmonics,producing modulation sidebands distributed at kfs±nfp,where fs and fp denote the switching frequency and pulse frequency,respectively.Based on the proposed model,the influences of pulse peak power,pulse frequency,and pulse duty cycle on the conducted EMI spectrum were analyzed.Finally,an experimental platform was established to validate the theoretical model under different pulse operating conditions. Experimental results showed that the proposed model accurately explained the evolution of the conducted EMI spectrum under pulse operating conditions.As the pulse peak power increased,the harmonic amplitude of the converter input current increased correspondingly,resulting in a higher differential-mode conducted EMI level.Compared with steady-state operation,pulse operating conditions introduced additional low-frequency modulation components,leading to a more complicated conducted EMI spectrum.Increasing the pulse frequency generated denser modulation sidebands and caused the low-frequency EMI spectrum to evolve from discrete spectral components to a continuous spectral envelope.Variations in pulse duty cycle mainly redistributed the spectral envelope by changing the harmonic energy distribution of the pulse current.The predicted modulation sidebands agreed well with the experimental results.Moreover,the coupling among the input filter,parasitic parameters,and pulse current harmonics enhanced the input current oscillation under high-frequency pulse operating conditions.Compared with steady-state operation,the conducted EMI amplitude around 10 kHz and 50 kHz increased by approximately 25.82 dBμV and 23.23 dBμV,respectively. The results indicate that pulse load dynamics increase not only the complexity of the conducted EMI spectrum but also the electromagnetic safety risks of the power supply system.The coupling between low-frequency pulse harmonics and high-frequency switching harmonics aggravates local resonance,impedance mismatch,and dynamic instability,particularly under high-power and high-frequency pulse operating conditions.Therefore,pulse dynamic characteristics,converter switching harmonics,system impedance matching,and filter design should be jointly considered in conducted EMI analysis and electromagnetic safety assessment. The following conclusions can be drawn from the simulation analysis:(1)A multi-time-scale analytical model is established to describe the coupling mechanism between pulse load dynamics and converter switching harmonics.The analytical model reveals that the pulse current dynamically modulates the high-frequency switching harmonics,producing modulation sidebands distributed around the switching frequency and its multiples according to kfs±nfp.(2)Pulse peak power,pulse frequency,and pulse duty cycle affect different characteristics of the conducted EMI spectrum.Pulse peak power mainly determines the amplitude of differential-mode conducted interference,pulse frequency governs the sideband spacing and spectral spreading,whereas pulse duty cycle controls the spectral envelope and harmonic energy distribution.(3)Pulse load dynamics increase the input current oscillation and further aggravate the conducted electromagnetic environment by enhancing the risks of local resonance and dynamic instability.Consequently,electromagnetic safety assessment and EMI suppression for pulse load power supply systems should simultaneously consider pulse dynamic characteristics,converter switching behavior,and system impedance matching.

杨平;王彪;彭宇圣;范信添;王威

西南交通大学电气工程学院 成都 611756西南交通大学电气工程学院 成都 611756西南交通大学电气工程学院 成都 611756西南交通大学电气工程学院 成都 611756西南交通大学电气工程学院 成都 611756||成都新欣神风电子科技有限公司 成都 611731

信息技术与安全科学

脉冲负载传导电磁干扰差模干扰移相全桥变换器电磁安全

Pulsed power loadconducted electromagnetic interferencedifferential-mode interferencephase-shifted full-bridge converterelectromagnetic safety

《电工技术学报》 2026 (13)

4403-4416,14

国家自然科学基金资助项目(52277201,U25B20206).

10.19595/j.cnki.1000-6753.tces.260854

评论