建立了铅试金富集-原子吸收光谱法测定高银粗锡中金、重量法测定银的分析方法.实验结果表明:在称样量2.000 g,配料组成为四氧化三铅120 g、硼砂10g、碳酸钠40 g、二氧化硅10 g、淀粉7.5 g条件下,经熔融、灰吹处理,原子吸收光谱法测定金的相对标准偏差(RSD,n=7)为0.67%,重量法测定银的相对标准偏差(RSD,n=7)为0.31%;金银加标回收率分别为97.4%~101.0%和98.6%~99.8%;方法应用于实际样品分析,与碘化钾-电位滴定法测定银比对结果吻合,为粗锡精炼流程控制及伴生贵金属资源综合利用提供了可靠的分析方法.
An analytical method was established,adopting lead fire assay enrichment.Gold was determined by atomic absorption spectrometry and silver by gravimetry.The results show that under the conditions of sample weight 2.000 g,with 120 g lead tetroxide,10 g borax,40 g sodium carbonate,10 g silicon dioxide and 7.5 g starch after melting and cupellation,the relative standard deviation(RSD,n=7)of gold is 0.67%,and that of silver is 0.31%.The recoveries of gold and silver range from 97.4%to 101.0%and 98.6%to 99.8%respectively.Practical sample test data are consistent with those obtained by potassium iodide potentiometric titration.This method offers reliable support for crude tin refining process control and comprehensive utilization of associated precious metal resources.
王海文;杨海岸;罗伟赋;杨赟金;字富庭;施昱
昆明冶金研究院有限公司,云南 昆明 650031||有色金属强化冶金新技术全国重点实验室,云南 昆明 650031||云南省选冶新技术重点实验室,云南 昆明 650031昆明冶金研究院有限公司,云南 昆明 650031||有色金属强化冶金新技术全国重点实验室,云南 昆明 650031||云南省选冶新技术重点实验室,云南 昆明 650031昆明冶金研究院有限公司,云南 昆明 650031||有色金属强化冶金新技术全国重点实验室,云南 昆明 650031||云南省选冶新技术重点实验室,云南 昆明 650031昆明冶金研究院有限公司,云南 昆明 650031||有色金属强化冶金新技术全国重点实验室,云南 昆明 650031||云南省选冶新技术重点实验室,云南 昆明 650031昆明理工大学理学院,云南 昆明 650093昆明冶金研究院有限公司,云南 昆明 650031||有色金属强化冶金新技术全国重点实验室,云南 昆明 650031||云南省选冶新技术重点实验室,云南 昆明 650031
化学化工
高银粗锡铅试金原子吸收光谱法重量法金银富集
high-silver crude tinlead fire assayatomic absorption spectrometrygravimetrygoldsilverenrichment
《云南冶金》 2026 (3)
140-144,5
国家自然科学基金项目(52264031)
评论