首页|期刊导航|人民长江|叠梁门调控下乌东德水库下泄水温改善效果研究

叠梁门调控下乌东德水库下泄水温改善效果研究OA

Research on improvement effect of discharged water temperature from Wudongde Reservoir under stoplog gate operation

中文摘要英文摘要

分层取水措施是缓解水库低温水下泄的有效手段,明晰梯级水库实际运行后上游梯级分层取水措施的沿程效力传递与迟滞规律对构建联合水温调控体系具有重要意义.利用 CE-QUAL-W2 模型构建了乌东德水库立面二维水动力水温数学模型,基于2022 年调度过程设置了单层取水和叠梁门设计运行两种情景,定量分析了叠梁门对乌东德水库水温节律的影响及其下游衰减特性.结果表明:叠梁门运行可显著提高流动层位置,促使平均取水高程从935.10 m 抬升至952.20 m,促进表层水体掺混,使得叠梁门设计运行工况下垂向温差较单层取水工况最大降幅达2.3℃;叠梁门设计运行工况下,下泄水温较单层取水平均提高0.5℃,旬均改善0.1~1.0℃;受下游梯级调蓄影响,乌东德水库分层取水效果沿程衰减显著,平均改善幅度从坝下0.49℃降至向家坝坝下0.16℃,最大改善效果降幅达1.01℃,白鹤滩、溪洛渡和向家坝水库效力显现时间分别滞后16,53,62 d.研究成果可为优化梯级水库分层取水调度策略,保障流域生态用水安全提供科学依据.

Selective withdrawal strategy is an effective measure for alleviating low-temperature water discharge from reservoirs.Clarifying the downstream transmission and hysteresis patterns of selective withdrawal strategy effects from upstream reservoirs to downstream reservoirs in cascade reservoir systems is of great significance for establishing a joint water temperature regulation sys-tem.A two-dimensional hydrodynamic water temperature mathematical model of the Wudongde Reservoir was employed using the CE-QUAL-W2 model in this study,and based on the 2022 scheduling process,two scenarios of single-layer water intake and designed stoplog gate operation were set up.The impact of stoplog gate on the water temperature regime of Wudongde Reservoir and its downstream attenuation characteristics were quantitatively analyzed.The results show that the stoplog gate operation could significantly raise the position of the flow layer,increasing the average water intake elevation from 935.10 m to 952.20 m,promo-ting the mixing of surface water bodies,and resulting in a maximum reduction of 2.3℃in vertical temperature difference under the designed stoplog opration scenario compared to the single-layer intake scenario.Under the designed stoplog opration scenar-io,the discharged water temperature increased by an average of 0.5℃compared to single-layer water intake,with an average improvement of 0.1~1.0℃over ten days.Due to the regulation and storage effects of downstream cascade reservoirs,the effect of stoplog gate in Wudongde Reservoir has significantly declined along the way,with an average improvement range from 0.49℃to0.16℃,and a maximum improvement effect decrease of 1.01℃.The effective manifestation times at Baihetan Reservoir,Xilu-odu Reservoir,and Xiangjiaba Reservoir lagged by 16,53,and 62 days,respectively.The research results can provide a scientific basis for optimizing the selective withdrawal scheduling strategy of cascade reservoirs and ensuring basin-scale ecological water use security of the basin.

王浩宇;脱友才;陆波;邓云;邹俊文

四川大学 山区河流保护与治理全国重点实验室,四川 成都 610065四川大学 山区河流保护与治理全国重点实验室,四川 成都 610065水电水利规划设计总院有限公司,北京 100120四川大学 山区河流保护与治理全国重点实验室,四川 成都 610065四川大学 山区河流保护与治理全国重点实验室,四川 成都 610065

建筑与水利

水温分层取水CE-QUAL-W2模型叠梁门取水高程梯级水库乌东德水库

water temperatureselective withdrawal strategyCE-QUAL-W2 modelstoplog gatewater intake elevationcascade reservoirsWudongde Reservoir

《人民长江》 2026 (6)

108-115,8

国家重点研发计划项目(2022YFC3204200)水电水利规划设计总院有限公司科技项目(ZX-KJHB-20220006)

10.16232/j.cnki.1001-4179.2026.06.012

评论