模块化雷击电流模拟装置设计及实验OA

Design and experiment of modular lightning current simulation device

中文摘要英文摘要

针对雷击试验对脉冲电流发生器的需求,设计并研制了模块化的雷击电流模拟装置,用于模拟产生雷电直接效应和间接效应时的电流环境.模块化雷击电流模拟装置主要由 A、B、C、D四个模块构成,分别可产生雷击电流分量 A初始雷击电流、分量 B中间电流、分量 C持续电流、分量 D再击电流.基于理论分析和电路仿真对四个模块的电参数进行设计,其中模块 A和模块 D采用储能电容与气体开关的多支路并联放电方案,模块 B采用晶闸管放电方案,模块 C采用超级电容器模组与固态开关直接切断电流的方案.同时,考虑到不同场景对加载距离的不同需求,通过控制电缆参数、调波电阻及加载腔体结构使加载距离在 5~30 m范围内可调.在此基础上,研制了模块化雷击电流模拟装置并进行了初步实验测试,其输出电流波形指标满足 GJB 1389A-2005中对雷击电流波形的要求.雷击电流模拟装置集成在标准集装箱内,为不同场地下各类设备开展雷击试验提供了支持.

[Background]Lightning is a transient electrical discharge that occurs during thunderstorms.The current generated by lightning can reach up to 200 kA,causing significant damage to aircraft,overhead power lines,electronic information equipment,and field military equipment.Therefore,the lightning strike test is necessary.[Purpose]To address the requirements of the pulse current generators in the lightning strike test,a modular device for generating the lightning current is designed and developed in this study,which is used to simulate the direct effects and indirect effects of lightning current.[Methods]The modular lightning current simulation device is mainly composed of four modules A,B,C,and D,which can respectively generate the component A initial lightning current,component B intermediate current,component C continuous current,and component D restrike current of the lightning current.The electrical parameters of the four modules are designed based on the theoretical analysis and the circuit simulation.Module A and Module D adopt the multi-branch parallel discharge scheme of energy storage capacitors and gas switches.The thyristor is used in module B,and module C adopts the scheme to combine the super capacitor and the solid-state switch to cut off the current directly.Considering the requirements of different scenarios for the loading distance,the loading distance can be adjusted within the range of 5 meters to 30 meters by controlling the cable parameters,wave-shaping resistance and loading chamber.[Results]The modular device is developed and the preliminary experimental test is carried out.The current waveform output meets the requirements of the lightning current waveform in GJB 1389A-2005.The modular device is integrated into the standard container,which provides support for the lightning strike test of various equipment in different sites.[Conclusions]This work designs and develops a modular lightning current simulation device through theoretical analysis,circuit simulation,and experimental testing.The device can generate the lightning current waveforms that meet the standard,which provides support for the lightning strike tests.

董芃欣;刘宏伟;袁建强;朱建瑜;王杰;杨杰

中国工程物理研究院流体物理研究所 脉冲功率技术重点实验室,四川 绵阳 621900中国工程物理研究院流体物理研究所 脉冲功率技术重点实验室,四川 绵阳 621900中国工程物理研究院流体物理研究所 脉冲功率技术重点实验室,四川 绵阳 621900中国工程物理研究院流体物理研究所 脉冲功率技术重点实验室,四川 绵阳 621900中国工程物理研究院流体物理研究所 脉冲功率技术重点实验室,四川 绵阳 621900中国工程物理研究院流体物理研究所 脉冲功率技术重点实验室,四川 绵阳 621900

信息技术与安全科学

雷击电流雷电直接效应雷电间接效应脉冲电流发生器模块化装置

lightning currentdirect effects of lightningindirect effects of lightningpulse current generatormodular device

《强激光与粒子束》 2026 (7)

94-104,11

10.11884/HPLPB202638.250365