高锰酸盐指数(CODMn)是水环境评价的重要指标.基于高锰酸钾氧化显色原理的CODMn 快速检测试剂因具有操作简便和响应快速等优势而被广泛应用于现场监测.然而,其反应机理及测定误差来源尚缺乏系统性评估.针对此问题,本研究选取3种目前常用的CODMn 快检试剂,结合紫外-可见(UV-Vis)分光光度法与人工目测比色法,系统分析了其显色机理、定量特征和关键影响因素.结果表明,快检试剂在512~562 nm与588~622 nm区间存在与MnO4-向MnO42-转化相关的特征吸收带;体系的吸光度与CODMn 浓度在0~13 mg/L范围内呈良好的线性关系(r2>0.98);在较高浓度区间需引入MnO2 吸光度进行补偿校正以提高定量精度(r2>0.99).人工目测结果虽与CODMn 理论浓度值相关性良好,但受主观因素影响,其变异系数(CV)达到7%~20%,且在临界色阶处误差更大.水温、pH值和盐度通过影响反应动力学对测定结果产生明显影响,其中酸性条件和高盐度环境引起的系统偏差约大于15%,Ca2+可能通过水合效应和离子环境调节影响MnO4-还原过程.快检试剂测定结果整体高于国标法(GB 11892-1989)检测结果,以葡萄糖为还原剂时,国标法检测结果约为快检结果的53%,且此差异在复杂环境水体中进一步增大.本研究从反应机理与环境影响层面揭示了CODMn 快检方法的误差来源,并提出了校正思路,为其在不同水环境条件下的适用性评价与优化提供了有力依据.

Permanganate index(CODMn)is a critical indicator for water quality assessment.Rapid test kits based on the permanganate oxidation colorimetric principle are widely used for on-site monitoring due to their operational simplicity and fast response.However,a systematic evaluation of their reaction mechanisms and sources of measurement errors is still lacking.In this study,three representative CODMn rapid test kits were investigated using ultraviolet-visible(UV-Vis)spectrophotometry combined with visual colorimetry,aiming to elucidate their color development mechanisms,quantitative characteristics,and key influencing factors.The results indicated that the rapid test kits exhibited characteristic absorption bands at 512-562 nm and 588-622 nm,which were associated with the conversion of MnO4-to MnO42-.A good linear relationship between absorbance and CODMn concentration was observed in the range of 0-13 mg/L(r2>0.98).Within higher concentration ranges,introducing the absorbance of MnO2 as a compensation term was necessary to improve quantitative accuracy(r2>0.99).Although visual colorimetry showed good correlation with theoretical CODMn values,it was subject to subjective factors,with coefficients of variation(CV)ranging from 7%to 20%,and errors were more pronounced at critical color thresholds.Further analysis revealed that water temperature,pH value,and salinity significantly affected the measurement results by influencing reaction kinetics.Specifically,acidic conditions and high salinity caused systematic deviations of approximately 15%or more.Ca2+may indirectly influence the MnO4-reduction process through hydration effects and changes in the ionic environment.The CODMn values obtained by rapid test kits were generally higher than those determined by the standard method(GB 11892-1989).When glucose was used as the reducing agent,the result from the standard method was approximately 53%of that from the rapid test kits,and this discrepancy was further amplified in complex environmental water matrices.These findings revealed the error sources of CODMn rapid test kits from the perspectives of reaction mechanisms and environmental influences,and proposed a calibration approach,thereby providing a basis for evaluating and optimizing their applicability under different water environmental conditions.

王吉迪;汪浩;赵晓丽;周鹏飞;陈思莉;周书葵

南华大学土木工程学院,衡阳 421001||生态环境部华南环境科学研究所,广州 510530南华大学土木工程学院,衡阳 421001||生态环境部华南环境科学研究所,广州 510530中国环境科学研究院,环境基准标准与风险管控全国重点实验室,北京 100012南华大学电气工程学院,衡阳 421001南华大学土木工程学院,衡阳 421001||生态环境部华南环境科学研究所,广州 510530南华大学土木工程学院,衡阳 421001

高锰酸盐指数快速检测试剂高锰酸钾显色法环境水体影响因素

Permanganate indexRapid test kitsPermanganate colorimetryEnvironmental watersInfluencing factors

《分析化学》 2026 (6)

1093-1103,11

国家自然科学基金项目(No.42207465)资助. Supported by the National Natural Science Foundation of China(No.42207465).

10.19756/j.issn.0253-3820.261048