基于SCL配置描述模型的工程安装光控制模块数字仿真OA
Digital Simulation of Engineering Installation Optical Control Module Based on SCL Configuration Description Model
工程安装连接的光控制数据传输速度和稳定性相对较高,正逐渐替代传统电缆控制.为了充分发挥其潜力,需要对其进行准确的物理建模仿真.现有的SCD(substation configuration description)配置模型仅在虚拟连接方面进行建模,而在物理连接和数字描述方面还未完全实现虚实结合.因此,提出一种基于IEC 61850 SCL(substation configuration language)配置描述模型的工程安装光控制模块数字建模仿真技术和设计方案.所提出的方案使用SCL来定义光控制模块链路中各种智能电子装置(IED)、交换机、光纤配线架(ODF)、跳纤以及光缆等的物理模型结构、元素组成以及描述语言,并提供了相应的代码示例.此外,通过创建物理模型拓扑图和光缆链路联系拓扑关系图,可以生成与物理实际层次和连接关系相匹配的连接模型.在某工程中进行测试,结果表明所提出的模型完整地表达了所有设备和光控制连接信息,并通过了一致性和规范性等测试,模型一致性达97%,模型规范性、标准化和模型动态均超过98%,可以实现与SCD配置文件的虚拟和实际映射.
The optical control data transmission speed and stability of the engineering installation connection are relatively high,and the traditional cable control is gradually being replaced.To reach its full potential,it needs to be accurately and physically modeled and simulated.The existing substation configuration desaiption(SCD)configuration model is only modeled in terms of virtual connections,and the combination of virtual and real is not yet fully realized in terms of physical connections and digital descriptions.Therefore,a digital modeling and simulation technology and design scheme of the engineering installation optical control module based on the IEC 61850 substation configuration language(SCL)configuration description model is proposed.The scheme uses the SCL to define the physical model structure,element composition,and description language of various in-telligent electranic devices(IED),switches,optical fiber distribution frame(ODF),jumpers,and optical cables in the optical control module link,and provides corresponding code examples.In addition,by creating a physical model topology diagram and a fiber optic link connection topology diagram,a connection model can be generated that matches the physical reality hierarchy and connection relationship.The proposed model is tested in the engineering and the results show that it fully expresses all the equipment and optical control connection information,and passes the consistency and standardization tests,the proposed model consistency is 97%,and the model standardization,standardization and model dynamics are more than 98%,which can realize the virtual and actual mapping with the SCD configuration file.
王鹏洋;刘强;陈小红;陈璨;陈冠宇
广东电网能源发展有限公司,广东,广州 510000广东电网能源发展有限公司,广东,广州 510000广东电网能源发展有限公司,广东,广州 510000广东电网能源发展有限公司,广东,广州 510000广东电网能源发展有限公司,广东,广州 510000
信息技术与安全科学
IEC 61850SCL配置描述模型工程安装光控制模块智能装置
IEC 61850SCL configuration description modelengineering installationoptical control modulesmart devices
《微型电脑应用》 2026 (5)
57-62,6