高拱坝环境激励自动模态识别改进方法OA
Improved automatic modal identification method for high-arch dams under ambient excitation
高拱坝的安全运行对保障下游人民群众生命财产安全具有重要意义,长期模态追踪是揭示其动力特性和理解其状态演化的重要手段.该文提出了一种新型聚类距离度量公式,改进了环境激励下协方差驱动的随机子空间法(SSI-COV)+基于密度的噪声应用空间聚类(DBSCAN)模态参数自动识别方法.该公式将模态置信准则(MAC)作为分母,频率差作为分子,从而实现物理模态点簇内距离的收缩和物理-伪模态点间距离的放大.首先针对不同聚类距离度量,开展了SSI-COV识别模态点聚类距离的统计分析,证明该文提出的聚类距离度量公式仅将物理模态点集中在固定范围.然后以5自由度数值模型和实际拱坝为实例,对比了单组模态识别与连续自动模态识别结果,表明该文提出的聚类距离度量公式在单组模态识别中能更好地分离稳定图中的物理模态点和虚假模态点,并对不同振动模式的聚类簇进行分类;在连续自动模态识别中对弱激发的高阶振动模式有更好的识别效果,识别高阶模态点数量增幅超过30%.该方法在对混凝土坝动力特性进行长期监测方面具有良好的工程实用性,为深入掌握高拱坝长期性态演变提供了有力支撑.
[Objective]High-arch dams require reliable long-term monitoring to ensure safety in complex operating environments and under extreme loads.Vibration-based operational modal analysis under ambient excitation is well-suited for continuous deployment due to its passive and minimally intrusive nature.However,the vibration response under these conditions is often weak and susceptible to noise and non-stationary excitation.When covariance-driven stochastic subspace identification(SSI-COV)is applied,the stabilization diagram frequently becomes cluttered with a mixture of physical poles and spurious poles,complicating manual pole selection and diminishing the effectiveness of automated pole clustering,particularly for densely spaced modes and weakly excited higher-order modes.This study aims to enhance automated modal identification for high-arch dams by refining the clustering distance metric to better separate physical poles from spurious ones.[Methods]A classical workflow that combines SSI-COV with density-based spatial clustering of applications with noise(DBSCAN)is adopted and enhanced by redesigning the clustering distance metric.Conventional metrics typically use a weighted summation of frequency difference and mode-shape similarity,which may not fully capture the relationships between the two features and may falter when identifying densely spaced modes.In this study,a coupled distance formulation is introduced that directly integrates the modal assurance criterion(MAC)with the absolute frequency deviation and is placed in the denominator.When the mode-shape correlation between two poles is weak and MAC approaches 0,the distance increases significantly.By contrast,when the correlation is strong and MAC approaches 1,the distance reduces to the absolute frequency deviation.Consequently,pole pairs with simultaneously exhibit small frequency differences and highly consistent mode shapes are assigned minimal clustering distances,whereas those with large frequency differences or inconsistent mode shapes are pushed apart.This leads to a clearer separation of physical and spurious modes in the stabilization diagram,thus meeting requirements for automated clustering-based interpretation.A statistical analysis of clustering distances is then performed using the stabilization diagram from a high-arch dam dataset.Finally,the method is validated through two case studies.The first involves a five-degree-of-freedom numerical system excited by broadband white noise with added measurement noise;the responses are segmented into consecutive windows to test both single-window identification and continuous modal tracking.The second case utilizes multisensor field vibration data from an actual high-arch dam,including a representative short-duration record and a multiday dataset for continuous monitoring.For each case,the proposed formulation computes clustering distances,DBSCAN clusters the poles,and modal frequencies and damping ratios are extracted to evaluate clustering accuracy and the performance of automated identification.[Results]The distance-based statistical analysis reveals that the proposed metric enhances separability.Pole pairs that meet both feature-consistency conditions are clustered within a compact distance interval,whereas partially consistent or inconsistent pairs shift toward larger distances.In the numerical example,the proposed method produces physical clusters that are less prone to absorbing noise points compared to the baseline metric,leading to an approximately 31%increase in identified modal poles for weakly excited higher-order modes.In the real dam case,the baseline metric generates excessive clusters that are closely packed,making it difficult to form effective clusters with clear and interpretable boundaries.By contrast,the proposed method clearly identifies three clusters for the high-arch dam and achieves a 34%increase in recognized poles for the relatively higher-order mode during continuous identification.This suggests that the improvement is most significant for relatively higher-order modes,where the number of identified modal poles increases by approximately one-third compared to the baseline approach.[Conclusions]By integrating frequency and MAC in a division-based formulation,the proposed metric enhances the compactness of the identified clusters and enables stable distinction between physical and spurious poles,while also improving the identification of weakly excited higher-order vibration modes.This directly enhances the robustness of DBSCAN-based automated modal identification and continuous modal tracking for high-arch dams under ambient excitation.The method can be easily incorporated into existing SSI-COV workflows,as it mainly updates the distance-computation step,providing a practical solution for reliable long-term vibration-based dam monitoring.
齐智勇;陈超;向致谦;王进廷;武永恒;周舟
湖北省智慧水电技术创新中心,武汉 430000||中国长江电力股份有限公司,武汉 430000清华大学水利水电工程系,北京 100084清华大学水利水电工程系,北京 100084清华大学水利水电工程系,北京 100084湖北省智慧水电技术创新中心,武汉 430000||中国长江电力股份有限公司,武汉 430000中国长江电力股份有限公司,武汉 430000
建筑与水利
高拱坝自动模态识别协方差驱动的随机子空间法基于密度的噪声应用空间聚类聚类距离度量公式
high-arch damautomatic modal identificationcovariance-driven stochastic subspace identificationdensity-based spatial clustering of applications with noiseclustering distance metric
《清华大学学报(自然科学版)》 2026 (5)
1024-1035,12
国家自然科学基金重点项目(52494971,52339007)湖北省智慧水电技术创新中心开放研究基金项目(SDCXZX-JJ-2023-04)
评论