调频式核电管道减振试验研究OA
Study on Tuning Vibration Reduction Technology for Nuclear Power Tube
针对核电站管道振动幅值大、易引发疲劳失效与泄漏的问题,基于冲击激励搭建管道减振试验系统,以直径50 mm不锈钢管道为研究对象,采用200 g不锈钢小球、500 mm坠落高度的冲击激励方式,研究阻尼参数(0、3、5、8)、弹簧线径(0.6 mm、0.7 mm、0.8 mm)对减振效果的影响规律,并测试装置有效减振范围,同时分析试验误差来源.结果表明,阻尼参数对减振效果呈先增强后减弱趋势,弹簧线径与减振效果呈正相关,其中阻尼参数为5、弹簧线径0.8 mm时减振最优,测点振动速度降至未减振理论测点振动速度的26.8%.试验结果可为核电管道振动治理提供定量依据与工程方案.
Aiming to address the problem of excessive vibration amplitudes of nuclear power plant tubes,which pose significant risks of failure and leakage,a tube vibration reduction test system was developed using impact excitation.Taking DN50 stainless steel pipe as the research object,an impact excitation method adopting a 200 g stainless steel ball with a drop height of 500 mm is adopted.The influence laws of damping parameters(0,3,5,8)and spring wire diameters(0.6 mm,0.7 mm,0.8 mm)on vibration reduction effect are investigated,the effective vibration reduction range of the device is tested,and the sources of test errors are analyzed simultaneously.The results show that the vibration reduction effect first increases and then decreases with the increase of damping parameters,and is positively correlated with spring wire diameter.The optimal vibration reduction performance is achieved at the damping parameter of 5 and spring wire diameter of 0.8 mm,where the vibration velocity of the measuring point is reduced to 26.8%of the theoretical vibration velocity without vibration reduction.The test result can provide quantitative basis and engineering scheme for vibration control of nuclear power tubes.
杨刚;周小剑;刘德军;骆雪莲;陆魏;王赞娥;陈灿;蒋翔;陈占锋
中核核电运行管理有限公司,浙江 嘉兴 314300中核核电运行管理有限公司,浙江 嘉兴 314300中核核电运行管理有限公司,浙江 嘉兴 314300中核核电运行管理有限公司,浙江 嘉兴 314300中核核电运行管理有限公司,浙江 嘉兴 314300中核核电运行管理有限公司,浙江 嘉兴 314300中核核电运行管理有限公司,浙江 嘉兴 314300中核核电运行管理有限公司,浙江 嘉兴 314300杭州电子科技大学,杭州 310018
信息技术与安全科学
核电管道调频减振装置管道振动阻尼参数弹簧线位
nuclear power tubetunable vibration reduction devicepipe vibrationdamping parameterspring wire diameters
《焊管》 2026 (5)
40-45,6
评论