首页|期刊导航|电气技术|基于改进型p-q算法的基波正序有功电流与谐波电流检测

基于改进型p-q算法的基波正序有功电流与谐波电流检测OA

Detection of fundamental positive-sequence active curent and harmonic current based on the improved p-q algorithm

中文摘要英文摘要

针对复杂电网环境下基波正序电流与指定次谐波电流提取困难的问题,本文提出一种改进型 p-q 算法,用于基波正序有功电流与谐波电流检测.以无功功率理论为基础,剖析在恶劣电网工况下传统 p-q 算法和 ip-iq 算法的局限性,通过融合 p-q 算法的鲁棒性、ip-iq 算法的实时性和谐波细化分量检测机制,形成更适配复杂工况的检测算法.仿真结果表明,与传统的基于电流平均值理论的检测法和二阶广义积分法相比,本文的改进算法在电网电压同时存在严重畸变与不对称时,仍能快速、准确地提取基波正序有功、无功电流,以及指定次谐波正序、负序电流的有功、无功分量.

To address the challenge of extracting fundamental positive-sequence current and specified-order harmonic currents in complex power grid environments,this paper proposes an improved p-q algorithm.Founded on the reactive power theory,the limitations of the traditional p-q algorithm and ip-iq algorithm under severe power grid operating conditions are analyzed.By fusing the robustness of the p-q algorithm,the real-time performance of the ip-iq algorithm,and a fine harmonic component detection mechanism,a detection algorithm more suitable for complex operating conditions is developed.Simulation results demonstrate that,compared with conventional detection methods based on the average-current theory and the second-order generalized integrator(SOGI)approach,the proposed improved algorithm can still quickly and accurately extract the active and reactive components of fundamental positive-sequence current,as well as the active and reactive components of specified-order harmonic positive-sequence/negative-sequence currents,even when the grid voltage suffers from simultaneous severe distortion and asymmetry.

高宇承;李锦彬;邵明

福建理工大学电子电气与物理学院,福州 350118福建理工大学电子电气与物理学院,福州 350118福建理工大学电子电气与物理学院,福州 350118

p-q 算法ip-iq基波正序有功电流谐波电流

p-q algorithmip-iqfundamental positive-sequence active currentharmonic current

《电气技术》 2026 (5)

11-19,9

福建省自然科学基金(2023J01951)校科研启动基金资助项目(GY-Z18059)

评论