体型因素及组织成分对成人胸部CT水当量直径的体型特异性剂量估算的影响OA
Impact of Individual Body Shape Factors and Tissue Contents on the Water Equivalent Diameter of Size-specific Dose Estimations in Adult Chest CT
目的:探讨个体的体型因素及组织成分对成人胸部水当量直径的体型特异性剂量估算(SSDEWED)的影响.方法:收集在本院行胸部CT平扫的成人受检者205例,采集其个体信息(身高、体重、身体质量指数(BMI));在中间层面的横断位图像上测量胸廓的平均CTROI值、横断面积AROI、左右径、前后径;测量整个扫描范围的脂肪含量、脂肪体积和肌肉含量、肌肉体积;计算前后径/左右径、扫描长度、扫描长度/左右径;获取受检者的容积CT剂量指数(CTDIvol),计算出所有受检者中间层面的SSDEWED的数值.分析脂肪含量、肌肉含量、脂肪体积、肌肉体积、BMI、横断面积AROI、左右径、前后径、扫描长度、扫描长度/左右径比、前后径/左右径比与SSDEWED的相关性.结果:脂肪含量、脂肪体积、肌肉体积、BMI、横断面积AROI、左右径、前后径、扫描长度/左右径比与SSDEWED有显著正相关性;肌肉含量、前后径/左右径比值、扫描长度与SSDEWED无相关性.结论:多种个体体型因素及组织成分与SSDEWED有显著相关性,其中脂肪组织是影响SSDEWED的关键因素.
Objective:To investigate the impact of individual body size factors and tissue composition on the size-specific dose estimate(SSDEWED)based on water equivalent diameter for adult chest.Methods:A total of 205 adult subjects who underwent chest CT scans at our hospital were enrolled,and their individual information(height,weight,body mass index)was collected.The average CTROI value,cross-sectional area AROI,right left diameter,and anteroposterior diameter of the thorax on the axial images at the intermediate level were collected.The fat content,fat volume,muscle content,and muscle volume across the entire scanning range were recorded.The anteroposterior diameter/right left diameter,scan length,and scan length/right left diameter were calculated.The volume CT dose index(CTDIvol)of the subjects was obtained,and the SSDEWED values at the mid-level of all subjects were calculated.The correlations between fat content,muscle content,fat volume,muscle volume,BMI,cross-sectional ares AROI,right left diameter,anteroposterior diameter,scan length,scan length/right left diameter ratio,anteroposterior diameter/right left diameter ratio,and SSDEWED were analyzed.Results:Fat content,fat volume,muscle volume,BMI,cross-sectional AROI,right left diameter,anteroposterior diameter,scan length/right left diameter ratio are significantly positively correlated with SSDEWED.Muscle content,anteroposterior/right left diameter ratio,and scan length showed no correlation with SSDEWED.Conclusion:Multiple individual body size factors and tissue compositions are significantly correlated with SSDEWED,among which adipose tissue is the key factor influencing SSDEWED.
姜阳;唐文韬;胡然;胡勤勤;李刚静;张昊;余婷;张德川
湖南中医药大学中西医结合学院,长沙 410208||重庆市中医院放射科,重庆 400021重庆市中医院放射科,重庆 400021重庆市中医院放射科,重庆 400021重庆市中医院放射科,重庆 400021重庆市中医院放射科,重庆 400021重庆市中医院放射科,重庆 400021重庆市中医院放射科,重庆 400021湖南中医药大学中西医结合学院,长沙 410208||重庆市中医院放射科,重庆 400021
医药卫生
水当量直径容积CT剂量指数体型特异性辐射剂量估算脂肪含量
water equivalent diametervolume CT dose indexsize-specific radiation dose estimationfat content
《CT理论与应用研究》 2026 (3)
461-467,7
成都中医药大学"杏林学者"医院专项(多维度个体因素对水当量直径的体型特异性成人胸部辐射剂量的影响研究(YYZX2022136))重庆教育委员会科学技术研究计划(肝硬化肾损伤磁共振灌注成像评估(KJQN202415136))重庆市科卫联合医学科研重点项目(基于人工神经网络的个性化成人胸部低剂量CT扫描模型构建及其应用研究(2024ZDXM001))重庆自然科学基金面上项目(基于水当量直径的体型特异性成人胸部CT有效剂量估算模型的研究(cstc2021jcyj-msxmX0727))重庆自然科学基金面上项目(基于水当量直径的体型特异性剂量估算成人胸部个性化的低剂量阈值模型研究(CSTB2023NSCQ-MSX0295)).