首页|期刊导航|CT理论与应用研究|北京某郊区基层医疗机构成人头颅及胸部CT检查辐射剂量调查与分析

北京某郊区基层医疗机构成人头颅及胸部CT检查辐射剂量调查与分析OA

Investigation and Analysis of Radiation Dose in Adult Head and Chest CT Examinations at Primary Healthcare Institutions in a Suburban District of Beijing

中文摘要英文摘要

目的:调查北京某郊区基层医疗机构成人头颅和胸部CT检查的辐射剂量水平,评估其合理性,为建立该区域的诊断参考水平(DRL)提供依据.方法:基于辖区内 11家基层医疗机构的 15台CT设备,采集头颅和胸部CT检查的相关扫描参数及辐射剂量数据,统计分析剂量分布情况,同时与国内外DRL推荐值进行比较.结果:头颅CT的CT剂量指数(CTDI)和剂量长度乘积(DLP)的DRL分别为 59.83mGy和 814.08mGy·cm,胸部CT的容积CT剂量指数(CTDIvol)和DLP的DRL分别为13.68mGy和444.51mGy·cm,均低于我国行业标准.头颅CT的DRL优于大部分国家标准,其余DRL差异不大.三级医院的辐射剂量明显低于一级医院,且扫描参数和辐射剂量均存在显著差异.结论:本地区基层医疗机构的成人头颅和胸部CT辐射剂量总体处于合理水平,但部分基层医院的CT扫描参数有待优化,以进一步降低受检者的辐射风险.

Objective:To investigate the radiation dose levels of adult head and chest CT examinations in a grassroots medical institution in a suburban area of Beijing,evaluate their rationality,and provide a basis for establishing the diagnostic reference level(DRL)for this region.Methods:Based on 15 CT devices of 11 grassroots medical institutions within the jurisdiction,the relevant scanning parameters and radiation dose data of head and chest CT examinations were collected,the dose distribution was statistically analyzed,and comparisons were made with the recommended values of DRL from both domestic and international sources.Results:The DRL of CT dose index(CTDI)and dose-length product(DLP)for head CT was 59.83 mGy and 814.08 mGy·cm,respectively,while the DRL of volume CT dose index(CTDIvol)and DLP for chest CT was 13.68 mGy and 444.51 mGy·cm,both of which were lower than the industry standards in China.The DRL of head CT was superior to most national standards,and the differences in other DRLs were not significant.The radiation dose in tertiary hospitals was significantly lower than that in primary hospitals,and there were significant differences in both scanning parameters and radiation doses.Conclusion:The overall radiation dose of adult head and chest CT in grassroots medical institutions in this region is within a reasonable range.However,the CT scanning parameters of some grassroots hospitals need to be optimized to further reduce the radiation risk for patients.

张斌;魁学妍;廖建勇;王旭;聂文环;冯洪杰;马严丽;王文武;张永县

北京市大兴区人民医院放射科,北京 102600北京市大兴区人民医院放射科,北京 102600北京市大兴区人民医院放射科,北京 102600北京市大兴区卫生健康委科技保障中心,北京 102699北京市大兴区卫生健康监督所,北京 102600北京市大兴区疾病预防控制中心,北京 102699北京市大兴区医院管理中心,北京 102699北京市大兴区榆垡镇中心卫生院,北京 102602首都医科大学附属北京同仁医院放射科,北京 100730

医药卫生

CT辐射剂量诊断参考水平

CTradiation dosediagnostic reference levels

《CT理论与应用研究》 2026 (3)

454-460,7

大兴区预防医学会科研课题基金(大兴区基层医疗机构CT检查辐射剂量调查与分析(XHKY202406)).

10.15953/j.ctta.2024.351

评论