扫描模式对胸主动脉CTA成像质量和辐射剂量的影响OA

Comparative Study of Different Scanning Modes in Thoracic Aortic Computed Tomography Angiography

中文摘要英文摘要

目的:探讨不同扫描模式对胸主动脉CTA图像质量和辐射剂量的影响.方法:回顾性分析未应用心电门控技术的 30例胸主动脉CTA(组 1,对照组),使用回顾性心电门控的 30例冠脉CTA重建舒张期(组 2)和收缩期(组 3)时相,30例应用宽曝光脉冲前瞻性心电门控技术(组 4)共 4组图像的质量和辐射剂量.分别记录、计算 4组的图像质量客观指标CT值、噪声、信噪比(CNR)和辐射剂量指标容积CT剂量指数(CTDIvol).对图像质量进行四分法主观评价.对主客观指标分别统计分析.结果:客观指标CNR组 1与组 2、3、4均有差异,组 2~组 4间均无差异;主观评分两两比较组 2~组 4显著高于组 1,组 2~组 4间无差异.非门控组(组 1)、回顾门控组(组 2和组 3)和前瞻门控组(组 4)的CTDIvol分别为 13.70(11.87,16.58)、12.62(10.03,15.01)和 11.54(8.92,15.56),差异无统计学意义.结论:在胸主动脉CTA中推荐使用窄曝光脉冲的前瞻性心电门控收缩期或舒张期扫描,可显著提高胸主动脉心脏段图像质量并降低辐射剂量.

Objective:This study aimed to compare the effects of different scanning modes on image quality and radiation dose in thoracic aortic computed tomography angiography(CTA).Methods:The image quality and radiation dose of 30 cases of thoracic aortic CTA(Group 1,control group),30 cases of retrospective CTA diastolic phase(Group 2)and systolic phase(Group 3),and 30 cases of wide-exposure pulse prospective electrocardiogram(ECG)(Group 4)were retrospectively analyzed.The CT value,noise,contrast-to-noise ratio(CNR),signal-to-noise ratio(SNR),and radiation dose(volume CT dose index(CTDIvol))were recorded and measured.The image quality was evaluated subjectively using the four points method.The subjective and objective indicators were analyzed statistically.Results:No differences were observed in the objective indexes of noise,CNR and SNR among the groups.The subjective score of pairwise comparison of Groups 2-4 was significantly higher than that of Group 1,and no difference was observed among Groups 2-4.The CTDIvol values of the non-gated group(Group 1),retrospective gated groups(Groups 2 and 3),and prospective gated group(Group 4)were 13.70(11.87,16.58),12.62(10.03,15.01),and 11.54(8.92,15.56),respectively,without a statistically significant difference.

张雨虹;马梓轩;胡玲静;吴宁;张永县

首都医科大学附属北京同仁医院放射科,北京 100730||首都医科大学燕京医学院,北京 101300首都医科大学附属北京同仁医院放射科,北京 100730首都医科大学燕京医学院,北京 101300首都医科大学燕京医学院,北京 101300首都医科大学附属北京同仁医院放射科,北京 100730

医药卫生

体层摄影胸主动脉造影术心电门控技术辐射剂量

tomographythoracic aortic angiographyECG-gating technologyradiation dose

《CT理论与应用研究》 2026 (3)

434-439,6

北京市教育科学"十四五"规划2024年度一般课题(CDDB24223).

10.15953/j.ctta.2024.346

评论