首页|期刊导航|四川水力发电|某水电站机组水导瓦温升高原因分析及处理

某水电站机组水导瓦温升高原因分析及处理OA

Analysis and treatment of temperature rise in turbine guide bearings of the units of a hydropower project

中文摘要英文摘要

通过对某水电站机组出现的水导轴承瓦温升高现象进行分析,最终得出更换水导冷却器过程中水导轴承支架发生变形导致部分水导瓦间隙变小和环境温度升高两方面的原因导致水导瓦温升高的结论,为水电站同类型水轮发电机组出现导轴承瓦温升高现象时提供分析依据和参考思路.

By analysing the phenomenon of temperature rising in the turbine guide bearings of the units of a hy-dropower project,it was concluded that the temperature rise in the guide bearings was caused by two factors:deformation of the guide bearing support during the replacement of the guide bearing cooler,which led to a re-duction in the clearance of some guide bearing pads,and an increase in ambient temperature,which provides a-nalysis basis and reference for addressing similar high-temperature issues in guide bearings of the units of a hy-dropower project.

何勇;王文超

雅砻江流域水电开发有限公司,四川 成都 610051雅砻江流域水电开发有限公司,四川 成都 610051

能源科技

水导轴承支架发生变形水导瓦间隙环境温度水导瓦温升高

the guide bearing supportdeformationguide bearing gapsenvironmental temperaturetempera-ture rise in turbine guide bearings

《四川水力发电》 2026 (2)

90-95,6

10.20196/j.cnki.scslfd.20260219