首页|期刊导航|中国输血杂志|2024年度全国血站实验室核酸检测混样拆分错项数据分析

2024年度全国血站实验室核酸检测混样拆分错项数据分析OA

Data analysis of resolution discrepancies in minipool nucleic acid testing:A 2024 national study of Chinese blood stations

中文摘要英文摘要

目的 探讨 2024 年度全国血站实验室 PCR 混样拆分检测模式中拆分错项的发生率、特征及相关影响因素.方法 采用全国性多中心横断面研究设计,纳入 334 家上报酶免非反应性核酸反应性数据的血站实验室,其中296 家采用 PCR 混样拆分检测模式,检测总量 12 536 273 份.对混样拆分数据进行系统分析,主要观察指标包括混样反应性率、拆分反应性率及拆分错项率,并按不同试剂、检测项目及 Ct 值水平进行亚组分析.同时结合实验室调查和原始扩增曲线复核,探讨潜在原因.结果 2024 年全国平均混样反应性率为0.15%,拆分反应性率为57.86%,各试剂拆分反应性率随 Ct 值增加而逐渐下降.全年全国平均拆分错项率为 0.081‱(102/12 536 273),17.91%(53/296)家实验室发生错项.9 种试剂出现拆分错项,错项模式具有试剂特异性,A2 试剂多见混样 HBV 拆分为HIV(36.36%),D1 试剂多见混样 HBV 拆分为 HCV(38.89%),E 试剂多见混样 HIV 拆分为 HBV(48.00%).错项标本 Ct 值较高,HBV 错项标本混样 Ct 值中位数>38,HCV 及 HIV 混样 Ct 值中位数>40.16 家实验室调查结果显示,多数错项标本扩增曲线存在"翘尾",部分与交叉污染或试剂批次问题相关.结论 我国血站 PCR 混样拆分检测模式下拆分错项发生率低,但存在试剂差异与实验室差异,拆分错项与低病毒载量、试剂性能及实验室操作密切相关.

Objective To investigate the incidence,characteristics,and influencing factors of resolution discrepancies within the minipool(MP)testing model across Chinese blood station laboratories in 2024.Methods A nationwide,multi-center,cross-sectional study was conducted,including 334 blood station laboratories that reported nucleic acid reactive data among enzyme immunoassay non-reactive samples.Of these,296 laboratories adopted the pool resolution model,with a total of 12 536 273 samples tested.Systematic analysis was performed on resolution data,focusing on the MP-NAT reactivity rate,the pool resolution concordance rate,and the resolution discrepancy rate.Subgroup analyses were conducted based on reagent types,viral targets,and Ct values.Potential causes were further explored through laboratory surveys and re-exami-nation of raw amplification curves.Results In 2024,the national average MP-NAT reactivity rate was 0.15%.The overall pool resolution concordance rate was 57.86%,which showed a gradual decline as Ct values increased across all reagents.The national average resolution discrepancy rate was 0.081‱(102/12 536 273),with 17.91%(53/296)of laboratories re-porting at least one discrepancy.Nine reagent types were associated with these events,exhibiting reagent-specific patterns.For Reagent A2,the predominant discrepancy was HBV reactive pools resolving as HIV(36.36%);for Reagent D1,HBV pools frequently resolved as HCV(38.89%);and for Reagent E,the most common pattern was HIV pools resolving as HBV(48.00%).These resolution discrepancies were strongly associated with high Ct values:the median pool Ct for HBV excee-ded 38,while those for HCV and HIV both exceeded 40.Investigations across 16 laboratories revealed that most discrepant samples exhibited"tailing"amplification curves,with some cases linked to cross-contamination or reagent batch-specific is-sues.Conclusion While the incidence of resolution discrepancies in the MP-NAT model remains low in China,variations exist across different reagents and laboratories.These discrepancies are closely associated with low viral load,reagent per-formance,and laboratory operational practices.

闫颖;何清;郑伟;马洁;常乐;姬慧敏;孙慧珍;王露楠

北京医院(国家老年医学中心),国家卫生健康委临床检验中心,老年疾病国家临床医学研究中心,国家卫生健康委老年医学重点实验室,中国医学科学院老年医学研究院,北京 100730云南昆明血液中心,云南 昆明 650000哈尔滨市血液中心(黑龙江省血液中心),黑龙江 哈尔滨 150056北京医院(国家老年医学中心),国家卫生健康委临床检验中心,老年疾病国家临床医学研究中心,国家卫生健康委老年医学重点实验室,中国医学科学院老年医学研究院,北京 100730||北京医院(国家老年医学中心)生物治疗中心,老年疾病国家临床医学研究中心,国家卫生健康委老年医学重点实验室,中国医学科学院老年医学研究院,北京 100730北京医院(国家老年医学中心),国家卫生健康委临床检验中心,老年疾病国家临床医学研究中心,国家卫生健康委老年医学重点实验室,中国医学科学院老年医学研究院,北京 100730北京医院(国家老年医学中心),国家卫生健康委临床检验中心,老年疾病国家临床医学研究中心,国家卫生健康委老年医学重点实验室,中国医学科学院老年医学研究院,北京 100730北京医院(国家老年医学中心),国家卫生健康委临床检验中心,老年疾病国家临床医学研究中心,国家卫生健康委老年医学重点实验室,中国医学科学院老年医学研究院,北京 100730北京医院(国家老年医学中心),国家卫生健康委临床检验中心,老年疾病国家临床医学研究中心,国家卫生健康委老年医学重点实验室,中国医学科学院老年医学研究院,北京 100730||中国医学科学院 北京协和医学院,北京 100730

医药卫生

献血者血液筛查核酸检测混样拆分

blood donorsblood Screeningnucleic acid testingpool resolution

《中国输血杂志》 2026 (4)

423-429,7

中国医学科学院医学与健康科技创新工程项目(2021-I2M-1-060)

10.13303/j.cjbt.issn.1004-549x.2026.04.002

评论