大体积混凝土基础水化热温度场与应力场仿真模拟及裂缝控制研究OA

Simulation and Research on Crack Control of Hydration Heat Temperature Field and Stress Field of Mass Concrete Foundation

中文摘要英文摘要

为降低大体积混凝土因内外温差产生有害裂缝的风险,文中以某大型桥梁承台大体积混凝土基础为例,采用有限元软件ABAQUS 建立水化热温度场与应力场的三维仿真模型,系统模拟了混凝土的升温、峰值及降温全过程,揭示基础内部温度场与应力场的时空分布规律.结果表明,混凝土最高温升可达65.0℃,最大拉应力为2.8 MPa,得出基础中心区域为裂缝高风险区.基于仿真结果,文中提出了原材料优选、智能通水冷却等综合裂缝控制方案.实践证明,该方案有效将混凝土内外温差控制在25℃以内,最大拉应力降至1.5 MPa 以下,成功抑制有害裂缝的产生,为类似大体积混凝土工程的裂缝控制提供理论依据和实践参考.

To reduce the risk of harmful cracks in large-volume concrete due to the temperature difference between the inside and outside,taking the large-volume concrete foundation of a large bridge pier as the engineering background,the finite element software ABAQUS was used to establish a three-dimensional simulation model of the temperature field and stress field of hydration heat,systematically simulating the entire process of concrete heating,peak and cooling.Reveal the spatiotemporal distribution laws of the temperature field and stress field within the foundation.The results show that the maximum temperature rise of the concrete can reach 65.0℃,and the maximum tensile stress is 2.8 MPa.It is concluded that the center area of the foundation is a high-risk area for cracks.Based on the simulation results,a comprehensive crack control scheme including raw material selection and intelligent water cooling is proposed.Practical experience has shown that this scheme effectively keeps the temperature difference between the inside and outside of the concrete within 25℃,reduces the maximum tensile stress to below 1.5 MPa,and successfully suppresses the occurrence of harmful cracks,providing a theoretical basis and practical reference for crack control in similar large-volume concrete projects.

宋子平

中铁济南工程建设监理有限公司,山东 济南 250000

交通工程

大体积混凝土水化热温度场应力场有限元仿真裂缝控制

Mass concreteHeat of hydrationTemperature fieldStress fieldFinite element simulationCrack control

《江西建材》 2026 (2)

53-56,4

评论