首页|期刊导航|电器与能效管理技术|高压电池组单体电压检测分析与改进

高压电池组单体电压检测分析与改进OA

Analysis and Improvement of Single Cell Voltage Detection for High-Voltage Battery Packs

中文摘要英文摘要

针对高压电池组单体电压检测漏电流大、贮存时间短的问题,提出一种浮地电压检测方案.详细介绍浮地电压检测电路的设计方法,并对蓄电池组的漏电流进行理论计算,单体漏电流由3.3 mA减小至0.83 mA.基于Saber软件搭建仿真平台进行漏电流的仿真,并与计算电流进行对比验证,为后续产品设计提供理论依据.实现了极小漏电流的高压电池单体电压检测,满足了电池组长期运行与贮存的需求.

To address the issues of high leakage current and short storage time in high-voltage battery pack cell voltage detection,a floating ground voltage detection scheme is proposed.The design method of the floating ground voltage detection circuit is introduced in detail,and the leakage current of the battery pack is calculated theoretically,which reduces the individual cell leakage current from 3.3 mA to 0.83 mA.A simulation platform is built using Saber software to simulate the leakage current,and the results are compared with the calculated current for verification,providing a theoretical basis for subsequent product design.This achieves the voltage detection of high-voltage battery cells with minimal leakage current,meeting the requirements for the long-term operation and storage of battery packs.

王玉宝;李人杰;覃思明;许祺峰;刘婉婷

上海空间电源研究所,上海 200245上海电科院技术有限公司,上海 200063上海空间电源研究所,上海 200245上海空间电源研究所,上海 200245上海空间电源研究所,上海 200245

信息技术与安全科学

高压电池组单体电压检测浮地电压检测漏电流

high-voltage battery packsingle cell voltage detectionfloating ground voltage detectionleakage current

《电器与能效管理技术》 2026 (3)

17-22,6

10.16628/j.cnki.2095-8188.2026.03.003

评论