针对10kV配电柜交接试验技术展开探讨,系统阐述配电柜内核心设备的试验项目与操作规范.具体涵盖真空断路器的绝缘电阻、接触电阻、分合闸特性等试验,电流互感器和电压互感器的绝缘电阻、直流电阻、极性变比及励磁曲线等测试,无间隙金属氧化物避雷器与过电压保护器的绝缘电阻、直流参考电压及工频放电电压试验,以及母线的绝缘电阻、相序检查和工频耐压试验.同时,该研究明确试验后设备状态恢复要求及试验报告的编制标准.其研究成果为 10 kV 配电柜交接试验的规范化实施提供技术参考,有助于保障电力设备的安全稳定运行.

The handover test technology of 10 kV distribution cabinets is discussed,and the test items and operating specifi-cations for core equipment in the distribution cabinets are systematically elaborated.Specifically,it covers the insulation resis-tance,contact resistance,opening and closing characteristics of vacuum circuit breakers,the insulation resistance,DC resistance,polarity change ratio and excitation curve of current transformers and voltage transformers,the insulation resistance,DC reference voltage and power frequency discharge voltage tests of gapeless metal oxide lightning arresters and overvoltage protectors,as well as the insulation resistance,phase sequence inspection and power frequency withstand voltage test of buses.At the same time,the study clarified the requirements for equipment condition recovery after test and the standards for preparing test reports.Its research results provide technical reference for the standardized implementation of handover tests for 10 kV distribution cabinets and help ensure the safe and stable operation of power equipment.