CLLLC谐振变换器电流应力抑制策略OA
Current Stress Suppression Strategy for CLLLC Resonant Converter
采用调频控制的CLLLC谐振变换器,过谐振工况运行时会产生电流应力过大的现象.基于此,提出1种基于移相调频的控制策略,对其电流应力进行抑制.通过基波分量近似法建立移相调频控制下的谐振电流模型,依据变换器软开关条件与传输功率特性,求取隔离变压器一、二次侧内移相值,结合调频控制所得开关频率共同作用于变换器,进而减小谐振电流应力.最后,搭建CLLLC谐振变换器电路仿真模型与实验系统对分析结论进行验证,结果表明所提策略对电流应力有显著抑制作用.
Under over-resonant operating conditions,a CLLLC resonant converter with frequency modulation control will generate excessive current stress.On the basis,a control strategy based on phase-shift frequency modulation is proposed to suppress the current stress.A resonant current model under phase-shift frequency modulation control is established by the first harmonic approximation method.According to the soft switching condition and transmission power characteristics of the converter,the phase-shift values on the primary and secondary sides of the isolation transformer are obtained.Combined with the switching frequency obtained by frequency modulation control,the resonant current stress is reduced.Finally,a circuit simulation model and an experimental system of the CLLLC resonant converter were built to verify the analytical conclusions,and results show that the proposed strategy has a significant inhibitory effect on current stress.
张新闻;刘百林;杨树德
北方民族大学电气信息工程学院,银川 750021北方民族大学电气信息工程学院,银川 750021扬州大学电气与能源动力工程学院,扬州 225127
信息技术与安全科学
CLLLC谐振变换器电流应力调频控制软开关
CLLLC resonant convertercurrent stressfrequency modulation controlsoft switch
《电源学报》 2026 (2)
91-100,10
宁夏自然科学基金资助项目(2023AAC03281)国家自然科学基金资助项目(52367018)This work is supported by Ningxia Natural Science Foundation under the grant 2023AAC03281National Natural Science Foundation of China under the grant 52367018