基于单片机的固定电话未接来电告警系统设计OA
Design of a Missed Call Alarm System for Landline Phones Based on a Single-chip Microcomputer
针对大多数型号的固定电话缺乏未接来电提醒功能可能导致遗漏重要来电的问题,设计了一套基于AVR单片机的固定电话未接来电声光告警系统并搭建了应用测试平台.系统通过预处理电路对电话线信号进行降压与电平转换,利用单片机ADC模块对处理后的信号进行采样与特征分析,并采用有限状态机(FSM)模型准确识别电话的空闲、振铃、摘机与挂机状态.当检测到振铃后未在设定时间内摘机时,系统通过光耦隔离的驱动电路启动声光报警器.测试结果表明,该系统在不同呼叫场景下状态识别准确,告警触发可靠,能有效提醒使用者关注未接来电,降低因漏接电话带来的潜在风险.
To address the lack of missed call alerts in most existing landline phones,which can lead to missed important calls,a sound and light alarm system for landline missed calls based on an AVR microcontroller(ATmega16)is designed and implemented.The system processes the telephone line signal through a preconditioning circuit for voltage reduction and level shifting.The ADC module of single-chip microcomputer samples and analyzes the features of the processed signal,accurately identifying telephone states-idle,ringing,off-hook,and on-hook-using a Finite State Machine(FSM)model.When a ring is detected without a subsequent off-hook action within a set time,the system activates audible and visual alarms via an optocoupler-isolated driver circuit.Test results demonstrate that the system accurately identifies states across various calling scenarios and triggers alarms reliably,effectively alerting users to missed calls and thereby reducing potential risks associated with unanswered calls.
胡嘉耀
福州大学梅努斯国际工程学院,福建 福州 350108
信息技术与安全科学
固定电话未接来电单片机告警系统
landline phonemissed callSingle-chip Microcomputeralarm system
《现代信息科技》 2026 (5)
193-198,6