热矿水中高锰酸盐指数测定方法建立与优化研究OA
Study on establishment and optimization of the determination method for permanganate index in thermal mineral water
由于热矿水的高矿化度、天然有机物与还原性无机物共存及温度波动性的特点,传统滴定法存在终点颜色模糊、复杂成分干扰和高温挥发损失或低温反应不完全等问题.综合酸性高锰酸钾滴定法和分光光度法的优势,建立连续流动注射-酸性高锰酸钾分光光度法检测水质高锰酸盐指数(以O2计)的新型方法,以热矿水作为参比样本,对载流基质、酸性体系配比、出峰时间及脱气时间在内的试验条件进行优化,并与国标方法对比,结果表明:标准曲线线性良好,相关系数大于0.999 5,检出限为0.02 mg/L;准确度相对误差为0.3%,精密度相对标准偏差为0.9%,有效排除Fe2+、Cl-、S2-等干扰物的影响;与高锰酸钾滴定法相比,试剂消耗量、试剂配置时间、产生废液量及检测结果时间分别下降了 93%、88%、89%和88%.研究成果可服务于热矿水资源的科学管理,为高浊、高有机物水体的检测提供技术范本.
In view of the characteristics of high mineralization,coexistence of natural organic matter and reductive inorganic matter,and temperature fluctuation of thermal mineral water,the traditional titration method had problems such as blurred end-point color,interference from complex components,and volatilization loss at high temperatures or incomplete reaction at low temperatures.To address these issues,a new method for detecting water permanganate index(expressed as O2)based on continuous flow injection-acidic permanganate spectrophotometry was established by combining the advantages of the acidic permanganate titration method and spectrophotometry.Taking thermal mineral water as the reference sample,the experimental conditions including carrier matrix,acidic system ratio,peak time and degassing time were optimized,and the method was compared with the national standard method.The results showed that the standard curve had good linearity with a correlation coefficient higher than 0.999 5,and the detection limit was 0.02 mg/L;the relative error of accuracy was 0.3%,the relative standard deviation of precision was 0.9%,and the interferences from Fe2+,Cl-,S2-and other substances were effectively eliminated.Compared with the permanganate titration method,the reagent consumption,reagent preparation time,waste liquid output and result detection time were reduced by 93%,88%,89%,and 88%,respectively.The research results can serve the scientific management of thermal mineral water resources and provide a technical model for the detection of high-turbidity and high-organic-matter water bodies.
付娆;李丽;郝伟;王蕴平;王树芳
北京市地质环境监测所 北京 100195||城市地下水安全防控技术创新基地 北京 100195北京市地质环境监测所 北京 100195||城市地下水安全防控技术创新基地 北京 100195北京市地质环境监测所 北京 100195||城市地下水安全防控技术创新基地 北京 100195北京市地质环境监测所 北京 100195||城市地下水安全防控技术创新基地 北京 100195北京市地质环境监测所 北京 100195||城市地下水安全防控技术创新基地 北京 100195
化学化工
连续流动注射分光光度法酸性高锰酸钾滴定法热矿水高锰酸盐指数
continuous flow injectionspectrophotometryacidic potassium permanganate titration methodthermal mineral waterpermanganate index index
《北京水务》 2026 (1)
20-25,6