凝汽式机组旁路蓄热调峰方案变工况及经济性研究OA
Study on variable working condition and economy of regenerative heat storage peak regulation scheme for condensing units
将熔盐储热技术应用于凝汽式火电机组可提高机组调峰的灵活性.构建了一种与旁路耦合的二级蓄热系统,并将其应用于某 660 MW超超临界一次再热机组.以 30%THA为蓄热设计工况,设计了 4 种蓄热容量方案,应用EBSILON软件模拟研究了变工况下机组的调峰范围、蓄放热时长、调峰成本和不同市场规则下蓄热调峰净利润的变化.结果表明:变工况运行时,存在蓄热可行域和放热可行域;蓄热过程中,蓄热起始工况在 40%~50%之间最低发电负荷率下降的幅度较大,且高温蓄热系统先达到蓄热设计容量;放热过程中,放热起始工况为 94.6%时即可达到VWO工况的负荷率,且高温蓄热系统先完成放热;不论何种方案,在 45%蓄热起始工况下蓄热调峰时,售电收益增加最大,寿命损耗成本的增加最小,蓄热调峰增加的总成本最低;在调峰辅助服务市场下,净利润的最大值在 40%蓄热起始工况下取得,而在容量市场下,净利润的最大值在 45%蓄热起始工况下取得;蓄热容量最小的方案的总成本增加最低,在 2种市场规则下的净利润均最大.
Applying the molten salt heat storage technology to condensing thermal power units can enhance the flexibility of peak shaving.A bypass two-stage heat-storage peak shaving scheme was proposed and applied in an ultra-supercritical 660 MW unit.Taking 30%THA as the design condition for the thermal storage system,four heat storage capacity schemes were designed.The EBSILON software was used to analyze the peak regulation range,heat storage and release duration,peak regulation cost,and the change of net profit from heat-storage peak-shaving under different market rules.The results show that during off-design operations,there exist feasible domains for both heat charging and discharging.During the charging process,when the initial operating condition is between 40%~50%,the decrease in minimum generation load ratio is most significant,with the high-temperature thermal storage system reaching its design capacity first.During the discharging process,when the initial operating condition is 94.6%,the load ratio equivalent to VWO condition can be achieved,with the high-temperature thermal storage system completing discharge first.Regardless of the implementation approach,peak-shaving through thermal storage achieves maximum electricity revenue growth while minimizing lifespan depreciation costs and overall system expenses.In the peak-shaving ancillary service market,net profit peaks at 40%heat-storage starting condition,whereas in the capacity market scenario,the maximum net profit occurs at 45%heat-storage starting condition.The scheme with the smallest heat storage capacity demonstrates the lowest total cost increase,with both market mechanisms yielding optimal net profits.
黄娅彤;郑莆燕;朱群志;叶子杰
上海电力大学 能源与机械工程学院,上海 200090上海电力大学 能源与机械工程学院,上海 200090上海电力大学 能源与机械工程学院,上海 200090上海电力大学 能源与机械工程学院,上海 200090
凝汽式机组蓄热调峰二级蓄热变工况运行经济性
condensing unitheat storage and peak regulationsecondary heat storagevariable operating conditioneconomy
《热力发电》 2026 (2)
128-138,11
甘肃省科学技术厅资助项目(22ZD11GA314) Project of Gansu Provincial Department of Science and Technology(22ZD11GA314)
评论