首页|期刊导航|广东水利水电|穿堤管道内导流片减振效果试验研究

穿堤管道内导流片减振效果试验研究OA

Experimental Study on the Vibration Reduction Effect of Guide Vanes Installed inside the Pipeline crossing the Embankment

中文摘要英文摘要

通过物理模型试验,研究在穿堤管道内部设置导流片的减振效果.试验设计了不同高度(10 mm、20 mm、30 mm)、不同偏转角度(30°、45°、60°)和不同数量(4个、6个、8个)的导流片组合方案,并对各方案的减振效果进行测试分析.试验结果表明:①导流片的偏转角度并非越大越好,较大偏转角的导流片虽能形成螺旋度较高的螺旋流,但会增加进口直管的负荷,通过增加导流片高度,可有效降低输水管道的能量损失;②设置导流片后产生的螺旋流能显著削弱弯管引起的振动不利影响.

This study conducted physical model tests by installing flow deflectors inside the pipeline.Various combinations of deflector height(10 mm,20 mm,30 mm),deflection angle(30°,45°,60°),and number(4,6,8)were tested to evaluate their vibration reduction effectiveness.The experimental results show that:① The deflection angle(θ)of the flow deflectors is not linearly correlated with performance.While larger deflection angles can generate spiral flow with higher helicity,they also impose a greater load on the inlet straight pipe.Increasing the height of the deflectors can effectively reduce the energy loss of the pipeline.② The spiral flow generated by the deflectors can significantly mitigate the adverse vibration effects induced by elbow pipes.

黄锦林;张建伟;叶合欣;杨灿

广东省水利水电科学研究院,广州 510635||广东省水动力学应用研究重点实验室,广州 510635华北水利水电大学水利学院,郑州 450046广东省水利水电技术中心,广州 510635中国电建集团北京勘测设计研究院有限公司,北京 100024

建筑与水利

穿堤管道减振措施导流片模型试验减振效果

cross-dike pipelinevibration reduction measuresflow deflectormodel testvibration reduction effect

《广东水利水电》 2026 (2)

30-34,5

国家自然科学基金项目(编号:52279133)广东省水利科技创新项目(编号:2024-07,2025-17)广东省水利水电技术中心科研项目(编号:JSZXWT202525).