随着近些年来我国新能源的快速发展,海底电缆将大规模的在海上风电及海岛联网中应用.与陆缆一样,海底电缆也存在接地方式选择的问题,但由于海缆的特殊结构以及敷设环境与陆缆区别较大,对于长度十几甚至几十公里的海底电缆如何在海床段、滩涂段、登陆段合理选择接地方式、设置接地点位置,是本研究需要探讨的和解决的问题.本研究提出通过EMTP计算海底电缆目前常采用的各种接地方式的感应电压和环流的方法,并通过Comsol多物理场有限元仿真软件进行对比验证,从而提出海底电缆合理的接地方案.同时通过实际工程案例验证EMTP模型的正确性.

With the rapid development of renewable energy in recent years in China,submarine cables are being widely used in offshore wind power and island interconnection.Similar to land cables,the selection of grounding methods for submarine cables is also a problem.However,due to the unique structure and laying environment of submarine cables,the selection of grounding methods and the positioning of groun-ding points for submarine cables with lengths ranging from a few kilometers to dozens of kilometers in sea-bed sections,intertidal sections,and landing sections are significantly different from land cables.The author aims to explore and solve this issue.The author also proposes a method to calculate the induced voltage and current for various grounding methods commonly used in submarine cables using the EMTP(Electromagnetic Transients Program)and verifies the results through a comparative study using the Comsol multiphysics finite element simulation software.Additionally,the correctness of the EMTP model is validated through practical engineering cases.

惠胜达;孙东旺;王战利

中国电建集团河南省电力勘测设计院有限公司,郑州 450007中国电建集团河南省电力勘测设计院有限公司,郑州 450007郑州祥和电力设计有限公司,郑州 450007

海底电缆接地位置接地方式EMTP及Comsol仿真计算实例验证

submarine cablegrounding positiongrounding modeEMTP and Comsolsimulation calcu-lationexample verification

《电瓷避雷器》 2026 (1)

53-66,14

10.16188/j.isa.1003-8337.2026.01.007

评论