首页|期刊导航|江苏水利|立式混流泵站运行噪声综合治理实践与效果分析

立式混流泵站运行噪声综合治理实践与效果分析OA

Comprehensive control practice and effectiveness analysis of operating noise in vertical mixed flow pumping stations

中文摘要英文摘要

针对立式混流泵站工作区噪声超标问题,通过现场实测与频谱分析,发现水泵机械噪声、水流与电机噪声以及联轴器空气动力噪声为主要噪声源.基于"源头屏蔽、路径消声、空间吸声"的综合治理思路,设计并实施了包括水泵层可拆卸式高效隔声罩、联轴层双层亚克力可视化隔声装置、联轴层上部通风消声装置及空间吸声在内的立体式降噪方案.治理后效果表明,各频段噪声均得到有效抑制,且方案未影响设备正常运行与巡检,为同类大型泵站的噪声控制工程提供了可借鉴的实践经验.

In response to the issue of excessive noise in the working area of a vertical mixed flow pump station,it was found through on-site measurements and spectral analysis that mechanical noise from the water pump,water flow and motor noise,and aerodynamic noise from the coupling were the main sources of noise.Based on the comprehensive management concept of"source shielding,path noise reduction,and spatial sound absorption",a three-dimensional noise reduction scheme was designed and implemented,including a detachable high-efficiency sound insulation cover for the water pump layer,a double-layer acrylic visual sound insulation device for the coupling layer,a ventilation and noise reduction device for the upper part of the coupling layer,and spatial sound absorption.The effectiveness of the treatment shows that the noise in all frequency bands has been effectively suppressed,and the scheme has not affected the normal operation and inspection of equipment,providing practical experience for noise control projects in similar large-scale pumping stations.

力刚;赵文军;潘卫锋;王开谟;颜红勤;蒋红樱

江苏省骆运水利工程管理处,江苏 宿迁 223800江苏省骆运水利工程管理处,江苏 宿迁 223800江苏省骆运水利工程管理处,江苏 宿迁 223800江苏省水利科教中心,江苏 南京 210029江苏省水利工程科技咨询股份有限公司,江苏 南京 210029江苏省水利工程科技咨询股份有限公司,江苏 南京 210029

建筑与水利

立式混流泵泵站噪声噪声控制隔声罩

vertical mixed flow pumppumping station noisenoise controlsoundproof enclosure

《江苏水利》 2026 (2)

69-72,4

江苏省水利科技项目(2025053)

评论