角接五相电机单相开路故障零序环流抑制方法OA

A zero-sequence current suppression method for pentacle-wired five-phase PMSMs under a single-phase open fault

中文摘要英文摘要

角接五相电机在单相绕组开路故障下存在典型零序环流,会引起相电流畸变和转矩波动等问题.为此,文中提出一种近似线性化控制方法,并结合比例-积分(proportional-integral,PI)控制实现对交变零序环流的有效抑制.首先,基于现有的星接五相电机容错控制模型,通过增设绕组相电流和电压的变换矩阵,给出一种角接五相电机的容错解耦控制方案;然后,推导零序环流和零序电磁转矩的非线性数学模型,并依据位置角度细分方法将非线性零序模型近似线性化,结合多维度PI控制器实现零序环流抑制;最后,进行仿真验证.实验结果表明,零序环流在未抑制前呈现具有一定幅值且基频波动的交流特性,在实行抑制方法之后,零序环流近乎为 0.相电流由抑制前的严重失衡和幅值过大状态转变为正常状态,转矩波动问题也明显改善.因此,在角接五相电机发生单相开路故障时,可以使用主动抑制零序环流的容错控制方法改善相电流畸变和转矩波动问题.

The zero-sequence circulating current(ZSCC)becomes prominent in the single-phase open-circuit fault of a pentacle-wired five-phase motor,and this phenomenon can lead to phase current distortion and torque fluctuation.To address this issue,a linear approximation control method is proposed,and proportional-integral(PI)control is used to suppress the alternating ZSCC.Firstly,a decoupling fault-tolerant control scheme for a pentacle-wired five-phase motor is introduced.This scheme extends the existing fault-tolerant control for star-wired five-phase motors by developing additional line-to-phase transformation matrices for the phase current and voltage.Then,a nonlinear mathematical relationship between ZSCC and zero-sequence electromagnetic torque is derived,and the nonlinear zero-sequence model is linearized using a subdivision method based on the rotor position.Combined with a multi-dimensional PI controller,ZSCC suppression is achieved.Finally,simulation and experimental results suggest that ZSCC exhibits an alternating characteristic with a significant amplitude oscillating at the fundamental frequency before suppression.ZSCC is effectively eliminated after the suppression method is applied.Also,the phase currents return to normal and can recover from the prior condition of severe imbalance and over-large amplitude,and the torque fluctuation issue is mitigated.In conclusion,when a single-phase open-circuit fault occurs in a pentacle-wired five-phase motor,the fault-tolerant control method with active suppression of ZSCC can be used to mitigate the phase current distortion and torque fluctuation.

周亚蒙;田兵;谭强;王涛

南京航空航天大学自动化学院,江苏 南京 211106南京航空航天大学自动化学院,江苏 南京 211106南京航空航天大学自动化学院,江苏 南京 211106浙江大学电气工程学院,浙江 杭州 310058

信息技术与安全科学

角接五相电机容错控制零序环流近似线性化比例-积分(PI)控制矢量控制

pentacle-wired five-phase motorfault-tolerant controlzero-sequence circulation current(ZSCC)approximate linearizationproportional-integral(PI)controlvectorial control

《电力工程技术》 2026 (2)

60-69,10

国家自然科学基金资助项目(52207061)航空科学基金资助项目(2022Z024052002)

10.12158/j.2096-3203.2026.02.007