X射线对储存血小板及其线粒体的影响OA

Impact of X-ray irradiation on stored platelets and their mitochondrial function

中文摘要英文摘要

目的 本研究旨在探讨临床常规X射线辐照剂量[平均辐照剂量(29.7±0.54)Gy]对血小板体外保存期间的功能、凋亡、活化状态及线粒体功能的影响,以期为优化血小板辐照策略提供实验依据.方法 本研究采用配对实验设计,选取 12 名健康供体的血小板,每份样本均分为辐照组与对照组(未辐照).所有样本均在标准血小板保存条件(22±2℃,持续振荡)下保存 5 d.通过流式细胞术检测血小板数量、凋亡率(Annexin V+阳性率)、活化标志物(CD62P、PAC-1、CD42b)及活性氧(ROS)水平.同时,采用线粒体特异性探针(如MitoTracker)评估线粒体数量、膜电位及三磷酸腺苷(ATP)含量变化.此外,结合透射电镜(TEM)观察血小板超微结构,重点关注线粒体形态、血小板膜完整性及颗粒分布情况.结果 保存 5 d内,辐照组血小板计数为(841.00±89.16)×109/L,对照组为(824.5±92.88)×109/L,两组差异无统计学意义(P=0.54);辐照组凋亡率为(4.94±1.39)%,对照组为(5.50±0.83)%,组间差异无统计学意义(P=0.31).活化指标方面,辐照组 CD62P 表达率为(24.32±7.57)%,对照组为(25.21±8.13)%(P=0.43);辐照组和对照组的 PAC-1 阳性率分别为(12.15±4.43)%和(11.75±3.40)%(P=0.44);CD42b 表达率分别为(12.14±4.43)%和(11.75±3.4)%(P=0.47);ROS 水平分别为(31.98±8.1)%和(30.64±5.89)%(P=0.45),均无统计学意义.线粒体功能指标中,辐照组线粒体数量为(55.88±11.49)%,对照组为(53.5±7.24)%(P=0.57);辐照组和对照组ATP含量分别为(42.45±5.29)%和(41.58±9.50)%(P=0.77);膜电位相对值分别为(59.53±10.89)%、(57.49±6.54)%(P=0.47),均未受明显影响.透射电镜观察进一步证实,辐照组血小板超微结构完整,线粒体形态正常,未见肿胀或空泡化等病理改变.结论 本研究评估了常规剂量X射线辐照对血小板保存质量的影响,证实该剂量辐照不会显著损害血小板的数量、凋亡率、活化状态及线粒体功能.这一发现为临床推广X射线辐照技术提供了重要实验依据,并提示其可能成为 γ 射线的安全替代方案.未来研究可进一步扩大样本量,并延长观察周期,以验证X射线辐照对血小板长期保存及输注后体内存活率的影响.

Objective To investigate the effects of clinical routine X-ray irradiation dose(average irradiation dose:29.7±0.54 Gy)on the function,apoptosis,activation state and mitochondrial function of platelets during in vitro storage,so as to provide experimental evidence for optimizing platelet irradiation strategies.Methods A paired experimental design was adopted.Platelets were collected from 12 healthy donors,and each sample was equally divided into the irradiated group and the control group(non-irradiated).All samples were stored for 5 days under standard platelet preservation conditions(22±2℃,continuous oscillation).Flow cytometry was used to detect platelet count,apoptosis rate(Annexin V+positive rate),activation markers(CD62P,PAC-1,CD42b)and reactive oxygen species(ROS)level.Meanwhile,mitochondrial-specific probes were used to evaluate changes in mitochondrial count,membrane potential and adenosine triphosphate(ATP)con-tent.Additionally,transmission electron microscopy(TEM)was employed to observe the ultrastructure of platelets,with a focus on mitochondrial morphology,platelet membrane integrity and granule distribution.Results Within 5 days of stor-age,the platelet count was(841±89.16)×109/L in the irradiated group and(824.5±92.88)×109/L in the control group,with no statistically significant difference between the two groups(P=0.54).The apoptosis rate was(4.94±1.39)%in the irradiated group and(5.50±0.83)%in the control group,showing no significant difference(P=0.31).For activation in-dicators,the CD62P expression rate was(24.32±7.57)%in the irradiated group versus(25.21±8.13)%in the control group(P=0.43).The PAC-1 positive rates were(12.15±4.43)%and(11.75±3.40)%in the irradiated group and con-trol group,respectively(P=0.44).The CD42b expression rates were(12.14±4.43)%and(11.75±3.4)%in the two groups,respectively(P=0.47).The ROS levels were(31.98±8.1)%and(30.64±5.89)%in the two groups,respec-tively(P=0.45).No significant differences were found in the above indicators.For mitochondrial function indicators,the mitochondrial count was(55.88±11.49)%in the irradiated group and(53.5±7.24)%in the control group(P=0.57).The ATP contents were(42.45±5.29)%and(41.58±9.50)%in the irradiated group and control group,respectively(P=0.77).The relative membrane potential values were(59.53±10.89)%and(57.49±6.54)%in the two groups,respectively(P=0.47).No significant difference were observed on the mitochondrial function-related indicators.TEM fur-ther confirmed that the ultrastructure of platelets in the irradiation group was intact,the mitochondrial morphology was nor-mal,and no pathological changes such as swelling or vacuolization were observed.Conclusion This study evaluated the impact of conventional-dose X-ray irradiation on platelet storage quality,confirming that this dose does not significant impair platelet count,apoptosis rate,activation status,or mitochondrial function.This finding provides important experimental evi-dence for the clinical promotion of X-ray irradiation technology and suggests its potential as a safe alternative to γ irradia-tion.Future studies could further expand the sample size and extend the observation period to verify the effects of X-ray irra-diation on long-term platelet storage and post-transfusion in vivo survival rate.

王娜;安宁;王晓莹;杨冬燕;张小乐;王亚娟;陈洁;胡兴斌;陈晨

空军军医大学第一附属医院 输血科,陕西 西安 710032空军军医大学第一附属医院 输血科,陕西 西安 710032空军军医大学第一附属医院 输血科,陕西 西安 710032空军军医大学第一附属医院 输血科,陕西 西安 710032空军军医大学第一附属医院 输血科,陕西 西安 710032空军军医大学第一附属医院 输血科,陕西 西安 710032曲江新区医院 输血科,陕西 西安 710000空军军医大学第一附属医院 输血科,陕西 西安 710032空军军医大学第一附属医院 输血科,陕西 西安 710032

医药卫生

X射线血小板储存线粒体

X-rayplatelet storagemitochondria