考虑台区运行控制及经济性提升的调容变压器配置评估方法OA
A configuration evaluation method for adjustable capacity transformers considering operational control and economic efficiency in distribution areas
当前已有调容变压器配置评估方法中存在着考虑因素单一、综合成本考虑不充分以及缺乏台区运行控制结果分析等问题.对此提出了一种综合考虑台区运行控制与经济性提升的调容变压器配置评估方法.首先基于二阶锥规划构建了潮流模型,通过台区优化运行控制结果得到典型日净负荷数据,作为调容变压器容量选取的基础数据.其次分析了影响调容变压器配置评估的多维关键因素,然后建立了面向经济性提升的综合成本评估指标.最后依据典型台区历史负荷数据,开展调容变压器配置算例分析.在考虑光伏接入和不考虑光伏接入的两种场景下,基于不同运行规划周期和容量裕量,通过与传统变压器配置方案进行对比,验证了文中所提调容变压器配置方案的有效性和优越性.
Current methods for configuring adjustable capacity transformers have several limitations.These include that the consideration of influencing factors is limited,the integration of comprehensive cost analysis is insufficient,and the assessment based on distribution transformer area operation and control results is absent.To address these issues,a configuration evaluation method for adjustable capacity transformers is proposed,which integrates operational control and economic performance.First,a power flow model is built using second-order cone programming.Based on the optimized operation of the distribution area,typical daily net load data are obtained to support ca-pacity selection of adjustable capacity transformers.Then,key factors affecting configuration decisions are analyzed,and a comprehensive cost evaluation index is developed.Case studies using historical load data are conducted under both photovoltaic(PV)and non-PV scenar-ios.The effectiveness and advantages of the proposed method are demonstrated by comparing different planning periods and capacity mar-gins with traditional configurations.
陆旦宏;李艳;杨婷;柏生奎;鱼泓漪
南京工程学院 电力工程学院、沈国荣学院,南京 211167南京工程学院 电力工程学院、沈国荣学院,南京 211167南京工程学院 电力工程学院、沈国荣学院,南京 211167南京工程学院 电力工程学院、沈国荣学院,南京 211167南京工程学院 电力工程学院、沈国荣学院,南京 211167
信息技术与安全科学
调容变压器配置台区运行控制经济性提升综合成本评估二阶锥规划
adjustable capacity transformer configurationdistribution transformer area controleconomic performance improvementcom-prehensive cost evaluationsecond-order cone programming
《电力需求侧管理》 2026 (1)
48-56,9
江苏省自然科学基金资助项目(BK20210932)
评论