首页|期刊导航|中国医药科学|阶梯多模式分娩镇痛的麻醉效果观察和对产妇及胎儿影响的研究

阶梯多模式分娩镇痛的麻醉效果观察和对产妇及胎儿影响的研究OA

A study on the anesthetic efficacy of stepwise multi-modal labor analgesia and its effects on maternal and fetal outcomes

中文摘要英文摘要

目的 探讨阶梯多模式分娩镇痛的麻醉效果及其对产妇和胎儿的影响.方法 采用回顾性研究方法,分析 2023 年 1 月至 2024 年 12 月于南京医科大学附属江苏盛泽医院产科接受分娩镇痛并完成自然分娩的150 例初产妇的临床资料.按分娩镇痛方式将产妇分为两组:传统硬膜外分娩镇痛组(C组,75 例)和阶梯多模式分娩镇痛组(D组,75 例).记录两组产妇第一、二、三产程的时长,以及入产房时、硬膜外镇痛前、硬膜外镇痛后 30 min、宫口开全时、胎儿娩出时、胎盘娩出时的视觉模拟评分法(VAS)评分;统计D组追加瑞芬太尼静脉微量泵注镇痛的例数;记录新生儿 1 min和 5 min Apgar评分,产妇低血压、恶心呕吐等不良反应发生情况及满意度评分.结果 两组产妇各产程时长比较,差异无统计学意义(P>0.05).与C组相比,D组产妇在硬膜外镇痛前、宫口开全时、胎儿娩出时的VAS评分显著降低,差异有统计学意义(P<0.05);D组有 12 例(16.0%)产妇需追加瑞芬太尼镇痛.两组新生儿 1 min和 5 min Apgar评分、产妇不良反应发生率比较,差异均无统计学意义(P>0.05).D组产妇满意度评分显著高于C组,差异有统计学意义(P<0.05).结论 阶梯多模式分娩镇痛方案镇痛效果确切,能更好地满足产妇的镇痛需求,且对产妇及胎儿无不良影响,产妇满意度高,具有临床应用价值.

Objective To investigate the anesthetic effect of ladder multi-modal labor analgesia and its impact on parturients and fetuses.Methods A retrospective study was conducted to analyze the clinical data of 150 primiparas who underwent labor analgesia and completed vaginal delivery in the Department of Obstetrics,Jiangsu Shengze Hospital Affiliated to Nanjing Medical University,from January 2023 to December 2024.The parturients were divided into two groups according to the labor analgesia methods:traditional epidural labor analgesia group(group C,75 cases)and ladder multi-modal labor analgesia group(group D,75 cases).The duration of the first,second,and third stages of labor was recorded.Visual analogue scale(VAS)scores for pain were documented at the following time points:upon admission to the labor room,before epidural analgesia,30 minutes after epidural analgesia,at full cervical dilation,during fetal delivery,and during placental delivery.The number of cases in group D requiring additional remifentanil intravenous micro-pump analgesia was counted.Neonatal 1-minute and 5-minute Apgar scores,incidence of adverse reactions(hypotension,nausea,vomiting,etc.)in parturients,and satisfaction scores were recorded.Results There was no significant difference in the duration of each labor stage between the two groups(P>0.05).Compared with group C,group D showed significantly lower VAS scores before epidural analgesia,at full cervical dilation,and during fetal delivery(P<0.05).Twelve cases(16.0%)in group D required additional remifentanil analgesia.No significant differences were observed between the two groups in neonatal 1-minute and 5-minute Apgar scores or the incidence of maternal adverse reactions(P>0.05).The satisfaction score of group D was significantly higher than that of group C(P<0.05).Conclusion The ladder multi-modal labor analgesia protocol demonstrates definite analgesic efficacy,better meets the analgesic needs of parturients,exerts no adverse effects on parturients and fetuses,and achieves high maternal satisfaction,indicating its clinical application value.

徐一刚;范建萍;吴涛;姚沈婷;梅芳

南京医科大学附属江苏盛泽医院麻醉科,江苏 苏州 215228南京医科大学附属江苏盛泽医院麻醉科,江苏 苏州 215228南京医科大学附属江苏盛泽医院麻醉科,江苏 苏州 215228南京医科大学附属江苏盛泽医院产科,江苏 苏州 215228南京医科大学附属江苏盛泽医院产科,江苏 苏州 215228

医药卫生

多模式分娩镇痛导乐分娩硬膜外静脉瑞芬太尼

Multi-modalLabor analgesiaDoula deliveryEpiduralIntravenousRemifentanil

《中国医药科学》 2025 (24)

94-97,121,5

南京医科大学附属江苏盛泽医院课题(YYKY202309).

10.20116/j.issn2095-0616.2025.24.19

评论