Experimental analysis of the influence of ambient temperature for a Loop Heat Pipe based Battery Thermal Management SystemOA
Experimental analysis of the influence of ambient temperature for a Loop Heat Pipe based Battery Thermal Management System
Marco Bernagozzi;Anastasios Georgoulas;Nicolas Miché;Marco Marengo
Advanced Engineering Centre,University of Brighton,Brighton BN2 4GJ,UKAdvanced Engineering Centre,University of Brighton,Brighton BN2 4GJ,UKAdvanced Engineering Centre,University of Brighton,Brighton BN2 4GJ,UKAdvanced Engineering Centre,University of Brighton,Brighton BN2 4GJ,UK||Department of Civil Engineering and Architecture,University of Pavia,Pavia 27100,Italy
battery thermal management system(BTMS)electric vehicle(EV)loop heat pipe(LHP)thermal chamberambient temperature
battery thermal management system(BTMS)electric vehicle(EV)loop heat pipe(LHP)thermal chamberambient temperature
《实验与计算多相流(英文)》 2024 (3)
242-252,11
The authors would like to thank the Advanced Engineering Centre at the University of Brighton for the financial support.