基于VIKOR方法分析通量平滑度对宫颈癌放疗剂量的影响OA

Effect Analysis of Flux Smoothness on the Radiotherapy Dose of Cervical Cancer Based on VIKOR Method

中文摘要英文摘要

目的 使用多准则妥协解排序(VIse Kriterijumska Optimizacija I Kompromisno Resenje,VIKOR)分析比较Monaco计划系统4种通量平滑度对宫颈癌放疗计划的影响.方法 选取本院40例宫颈癌患者为研究对象,按照PTV 50.4 Gy/28次的处方剂量,分别使用4种通量平滑模式(OFF、LOW、MEDIUM和HIGH)设计4组放疗计划,将处方剂量归一至95%的靶区体积后,使用SPSS 27.0软件进行单因素方差分析,比较各组之间差异,并使用VIKOR分析进行综合评估.结果 4组计划在靶区D98%(98%的靶区体积接受的最小剂量,其他依次类推)、D2%、Dmean(平均剂量)、均匀性指数、适形度指数、膀胱V50(器官接受至少50 Gy剂量的体积百分比,其他依次类推)、膀胱Dmean、膀胱正常组织并发症概率(Normal Tissue Complication Probability,NTCP)、小肠V30、小肠Dmean、小肠NTCP、直肠V50、直肠Dmean、直肠NTCP、左股骨头V20、左股骨头Dmean、右股骨头V20、右股骨头Dmean方面差异均无统计学意义(P>0.05),在机器跳数(Monitor Unit,MU)方面差异有统计学意义(P<0.05),且随着通量平滑程度增加,MU呈降低趋势.VIKOR分析结果显示LOW组为最优方案.结论针对宫颈癌临床放疗计划设计,Monaco计划系统4种通量平滑模式均满足临床治疗需求;随着通量平滑度的提高,MU呈逐渐降低趋势;VIKOR结果建议,可选择LOW模式以达到最优的剂量结果.

Objective To analyze and compare the effects of four flux smoothness levels of the Monaco planning system on radiotherapy planning for cervical cancer using vise kriterijumska optimizacija i kompromisno resenje(VIKOR).Methods Forty patients with cervical cancer in our hospital were selected as the research subjects.According to the prescribed dose of 50.4 Gy/28 times for PTV,four groups of radiotherapy plans were designed using four flux smoothing modes(OFF,LOW,MEDIUM and HIGH)respectively.After reducing the prescribed dose to 95%of the target area volume,One-way ANOVA was performed using SPSS 27.0 software to compare the differences among the groups,and VIKOR analysis was used for comprehensive evaluation.Results The four groups planned at D98%(the minimum dose received by 98%of the target area volume,and so on for the others),D2%,Dmean(average dose),homogeneity index,conformal index,and bladder V50(the volume percentage of the organ receiving at least 50 Gy dose,and so on for the others),the Dmean of the bladder,and the probability of normal tissue complication probability(NTCP)of the bladder,small intestine V30,small in-testine Dmean,small intestine NTCP,rectal V50,rectal Dmean,rectal NTCP,left femoral head V20,left femoral head Dmean,right femoral head V20,and right femoral head Dmean were no statistically significant differences(P>0.05).The difference in the number of monitor unit(MU)was statistically significant(P<0.05),and MU showed a decreasing trend with the increase of flux smoothness.The VIKOR analysis results showed that the LOW group was the optimal scheme.Conclusion For the design of clinical radiotherapy plans for cervical cancer,all four flux smoothing modes of the Monaco planning system can meet the clinical treatment requirements.With the improvement of flux smoothness,MU shows a gradually decreasing trend.The VIKOR results suggest that the LOW mode can be selected to achieve the optimal dose results.

孙宇;张武;刘灏;武曼莉;郝远翔

皖北煤电集团总医院放疗中心三病区,安徽 宿州 234000皖北煤电集团总医院放疗中心三病区,安徽 宿州 234000皖北煤电集团总医院放疗中心放射治疗室,安徽 宿州 234000皖北煤电集团总医院放疗中心放射治疗室,安徽 宿州 234000皖北煤电集团总医院放疗中心放射治疗室,安徽 宿州 234000

医药卫生

宫颈癌Monaco计划系统通量平滑正常组织并发症的概率(NTCP)多准则妥协解排序(VIKOR)放射治疗

cervical cancerMonaco planning systemflux smoothingnormal tissue complication probability(NTCP)vise kriterijumska optimizacija i kompromisno resenje(VIKOR)radiotherapy

《中国医疗设备》 2025 (5)

58-64,85,8

2023年度宿州市自筹资金项目(SZZCZJ202305)2023年度宿州市卫生健康科研项目(SZWJ2023a062)2022年度宿州市自筹资金项目(SZZCZJ202218).